background image

Contents:

1 no T3 Tap 
1 no Top Plate with Control Panel
1 no Drip Tray 
1 no Blue JG Chilled Pipe
1 no Clear Silicone Hose Hot Pipe
1 no Connector Cable 
1 no Waste Drain Pipe
1 no Fixings Set

Please Note:

  

Mains Installation Kit & Filters are 

supplied as extra items according 

to individual ordering requirement.

Main Body

Faucet

Control Panel

T3 Tap 

Water Inlet

Top Panel

Unit Carry Handle

Side Panel

Front Panel

Chilled Water Outlet

Drip Tray

Tap Mounting Plate

Connector Cable

Power Connection

On/Off Switch

Tap Connection

*Sparkling versions only

Contents:

1 no ProCore or Unit
1 no 2.0m Power Cord Set
1 no Co2 Regulator with Gauge & Connection tube*
1 no Ventilation Ducting Kit

ProCore™ Undercounter

CO2 Inlet*

Hot Water Outlet

Component/Feature Overview

Easy-fit Ventilation 

Base

Ventilation Chimney

Blue JG - Chilled

Clear Silicone Hose - Hot

Содержание T3

Страница 1: ...ntents NOTE This booklet to be left with appliance following installation Component Feature Overview Operation Functions Controls General Safety CO2 Bottle Installation Fault Finding User Guide Chilled Ambient Sparkling T3 T3 Tap systems Hot ...

Страница 2: ... positioning the appliance ensure the supply cord is not trapped or damaged WARNING Do not locate multiple portable socket outlets or portable power supplies at the rear of the appliance This appliance is intended to be used in household and similar applications such as Staff kitchen areas in shops offices and other working environments Farm houses and by clients in hotels motels and other residen...

Страница 3: ...et Control Panel T3 Tap Water Inlet Top Panel Unit Carry Handle Side Panel Front Panel Chilled Water Outlet Drip Tray Tap Mounting Plate Connector Cable Power Connection On Off Switch Tap Connection Sparkling versions only Contents 1 no ProCore or ProCore Unit 1 no 2 0m Power Cord Set 1 no Co2 Regulator with Gauge Connection tube 1 no Ventilation Ducting Kit ProCore Undercounter CO2 Inlet Hot Wate...

Страница 4: ...gulations by application of either The Building Regulations England and Wales The Building Regulations Scotland or The Building Regulations Northern Ireland In territories other than those listed the local regulations in force must be complied with The Water Supply Water Fittings Regulations England Wales and Northern Ireland or The Water Byelaws in Scotland The unit must not be installed where it...

Страница 5: ... eco mode to awaken unit press and hold any dispense icon The Unit will activate eco mode in the below instances Dispense inactivity Low room light level To turn on off eco mode tap the chilled icon 7 times and hold on the 7th 2 beeps will indicate Eco is on and 1 beep will mean Eco is off Warning Symbol Warning triangle symbol will illuminate and flash upon a fault The number of flashes relates t...

Страница 6: ...austic alkaline agent Always use responsibly and with care remembering that due to it s alkaline nature 5 sec 2Ltr 5 sec 11 12 13 14 15 16 17 18 19 1 1 0 1 1 1 1 1 2 1 1 3 1 1 4 1 1 5 1 1 6 1 1 7 1 18 1 1 9 1 20 Sanitisation Guide To be completed by a technician or service provider ...

Страница 7: ...lem Report Possible Cause Suggested Action No Water Dispensing Water Pressure Regulator Contact your distributor No Sparkling Water If applicable No CO2 pressure Check CO2 bottle regulator and non return valve Supply pressure should be 58 psi 3 5 4bar replace as necessary Carbonator Tank Not Filling Contact your distributor Poor Quality Carbonation If applicable Air in Carbonator Tank Isolate the ...

Страница 8: ...rt its weight During use this machine must remain in its upright position Adequate ventilation must be allowed for we recommend using the supplied ventilation ducting kit Keep the machine away from sunlight heat and moisture The environment where this machine is installed must be free of dust and corrosive explosive gases Copyright Borg Overström This guide is printed by Borg Overström and shall n...

Отзывы: