background image

Unit Carry Handle

Drip Tray

Hot Tank Commissioning

On initial start up the ‘Unlock’ and ‘Hot’ icon will be flashing, this means the unit is in commissioning mode. To commission 

the hot tank safely please follow the below steps:

1. Press the ‘Unlock’ icon then hold the ‘Hot’ icon to start filling the hot tank. This will time out after 30s.

2. To continue filling the tank, repeat step 1 as many times as is required until water flows from the tap outlet.

3. After water has been dispensed from the outlet, press and hold the ‘Unlock’ icon for 10 seconds until the unit beeps.

4. The ‘Unlock’ icon will now be solid and the ‘Hot’ icon slowly flashing. The ProCore or is now active.

*Expect dripping on hot dispense until the tank has reached temperature and initial dispense made. This will only occur on 

first heating cycle on initial start-up.

Installation Requirements

• 

Identify a suitable location for the ProCore unit. It should be positioned within 1.0m of the faucet, and within 2.0m 

of suitable services connections. Allow enough space to fit the ventilation ducting system.

•  The ProCore unit must be installed in accordance with the relevant requirements of:

•  The appropriate building regulations by application of either The Building Regulations (England and 

Wales), The Building Regulations (Scotland) or The Building Regulations (Northern Ireland). In territories 

other than those listed the local regulations in force must be complied with.

• 

The  Water  Supply  (Water  Fittings)  Regulations  (England,  Wales  and  Northern  Ireland)  or  The  Water 

Byelaws in Scotland.

•  The unit must not be installed where it is liable to freeze. If the unit is thought to be frozen it must not be switched 

on. It should be allowed to thaw and must then be thoroughly inspected to ensure it is undamaged.

•  Water: Mains potable water – internally regulated to 0.3MPa (3 bar)
•  Minimum to maximum ambient room operating temperature: 5°C - 35°C
•  CO2: Food Grade CO2 to be supplied
•  Min mains pressure 0.05MPa (0.5 bar)
•  Electricity: 10A supply – Earth Leakage Protected
•  Waste Drain Connection

CO2 Bottle Installation - Sparkling Versions Only

2

1

3

OFF

58 PSI

4

Unpack CO2 Regulator and fit 

elbow fitting to spigot outlet. 

Attach the regulator to the 

CO2 bottle, ensuring the small 

pressure relief vent in the stem 

is facing away from you or 

anyone else. Ensure the regulator 

is closed. Hand tighten securely.

Connect the assembled CO2 

bottle and regulator to the CO2 

inlet using a ¼” pipe.

Stand the cylinder in a suitable 

place. We recommend between 

3.5 - 4 bar (58 PSI) (max). Do 

not exceed 4 bar pressure. 

Содержание T3

Страница 1: ...ntents NOTE This booklet to be left with appliance following installation Component Feature Overview Operation Functions Controls General Safety CO2 Bottle Installation Fault Finding User Guide Chilled Ambient Sparkling T3 T3 Tap systems Hot ...

Страница 2: ... positioning the appliance ensure the supply cord is not trapped or damaged WARNING Do not locate multiple portable socket outlets or portable power supplies at the rear of the appliance This appliance is intended to be used in household and similar applications such as Staff kitchen areas in shops offices and other working environments Farm houses and by clients in hotels motels and other residen...

Страница 3: ...et Control Panel T3 Tap Water Inlet Top Panel Unit Carry Handle Side Panel Front Panel Chilled Water Outlet Drip Tray Tap Mounting Plate Connector Cable Power Connection On Off Switch Tap Connection Sparkling versions only Contents 1 no ProCore or ProCore Unit 1 no 2 0m Power Cord Set 1 no Co2 Regulator with Gauge Connection tube 1 no Ventilation Ducting Kit ProCore Undercounter CO2 Inlet Hot Wate...

Страница 4: ...gulations by application of either The Building Regulations England and Wales The Building Regulations Scotland or The Building Regulations Northern Ireland In territories other than those listed the local regulations in force must be complied with The Water Supply Water Fittings Regulations England Wales and Northern Ireland or The Water Byelaws in Scotland The unit must not be installed where it...

Страница 5: ... eco mode to awaken unit press and hold any dispense icon The Unit will activate eco mode in the below instances Dispense inactivity Low room light level To turn on off eco mode tap the chilled icon 7 times and hold on the 7th 2 beeps will indicate Eco is on and 1 beep will mean Eco is off Warning Symbol Warning triangle symbol will illuminate and flash upon a fault The number of flashes relates t...

Страница 6: ...austic alkaline agent Always use responsibly and with care remembering that due to it s alkaline nature 5 sec 2Ltr 5 sec 11 12 13 14 15 16 17 18 19 1 1 0 1 1 1 1 1 2 1 1 3 1 1 4 1 1 5 1 1 6 1 1 7 1 18 1 1 9 1 20 Sanitisation Guide To be completed by a technician or service provider ...

Страница 7: ...lem Report Possible Cause Suggested Action No Water Dispensing Water Pressure Regulator Contact your distributor No Sparkling Water If applicable No CO2 pressure Check CO2 bottle regulator and non return valve Supply pressure should be 58 psi 3 5 4bar replace as necessary Carbonator Tank Not Filling Contact your distributor Poor Quality Carbonation If applicable Air in Carbonator Tank Isolate the ...

Страница 8: ...rt its weight During use this machine must remain in its upright position Adequate ventilation must be allowed for we recommend using the supplied ventilation ducting kit Keep the machine away from sunlight heat and moisture The environment where this machine is installed must be free of dust and corrosive explosive gases Copyright Borg Overström This guide is printed by Borg Overström and shall n...

Отзывы: