Borg & Overstrom f4 Скачать руководство пользователя страница 4

GB

Installation continued

5. Avoid tilting the machine during installation.
If the machine has been tilted excessively for
more than a few minutes during or before
installation, leave to stand for approximately
one hour before switching on.

6. Allow an air gap of at 100mm each side
and at the front of the machine.

7. Once positioned and levelled remove the
Front panel.

8. Unpack the swan-neck tap, fasten to the sink
top and connect to the water pipework.  If

necessary remove the sink top to carry this out.
(See page 3)

9. Install/connect the waste water system as
selected.  Do not use the fountain without any
waste system being fitted to the open end of
the waste fitting.

10. An access port hole for services is
provided on the rear of the cabinet and there is
a closed rubber   grommet pre-fitted which can
be opened to protect the cabinet and pipe
where it passes through the access port hole.

IMPORTANT!

ALWAYS ENSURE SECURITY CLIPS
ARE USED ON ALL WATER AND
CO2 CONNECTIONS.

Water Connection

1. Connect the inlet water supply to the 3/4”
threaded connection at the rear. (Fit a Pressure
Reducing Valve to regulate the water pressure
as required.  Max 3.5 bar) Ensure a stop tap
valve for the water is easily accessible. We
also recommend the use of a water-block and
non-return valve to be fitted.

2. We recommend that a filter is also fitted to
ensure water of the highest quality. A mounting
bracket is provided inside the cabinet. Always
pre-flush any filter before fitting.

3. Switch on the water and check the water
tightness of all connections and fittings.

to vent the system until the water dispenses.
This may take time while the system fills.  Flush
through at least 5 ltrs of clean water.  The
fountain is supplied in clean condition but it is
the responsibility of the installer to ensure an
acceptable standard of hygiene.  If necessary
carry out a sanitization procedure upon initial
installation at this point taking care to avoid
contaminating any filters as fitted.  Continue to
ensure water tightness of all connections and
fittings.

5. Connect the power cord set provided into
the connection point inside the cabinet and
securely fasten the cable in the 2 cable clamps
also provided. Switch on the electrical supply.

4. Open both the swan-neck and bubbler tap

Содержание f4

Страница 1: ...3 3 4 5 5 6 6 7 8 Contents Description Major Components Parts to Assemble Installation Water Connection Operation Maintenance Performance Data Fault Diagnosis Guide Electrical Diagram General Safety Advice Maintenance Removal chilled GB ...

Страница 2: ...ction 6 G Connection 7 Fan 8 Condenser 9 Compressor 10 Adjustable Feet 19 Top Panel 20 Bubbler Faucet 21 Swan neck Faucet 22 Push fit Connector of the Swan neck Faucet 23 Cold Tank Fix Brackets 24 Waste Tray 25 Flexible Waste pipe 26 Terminal Box 27 Power Cord Set 11 Tank Insulation 12 Front Panel 13 Drain Plug 14 Cold Water Tank 15 Connector of Cold Tank Outlet Water 16 Connector of Cold Tank Inl...

Страница 3: ...th any local regulations that may be applicable to this type of installation 1 Install near to a convenient place to connect to a mains pressure water supply of drinking water quality and 220 240V 50Hz electrical supply 2 Avoid areas exposed to excessive heat humidity rain or snow or direct contact with water spray or splashing 3 Avoid positions of direct sunlight or solar heat 4 Install only on f...

Страница 4: ...e 3 4 threaded connection at the rear Fit a Pressure Reducing Valve to regulate the water pressure as required Max 3 5 bar Ensure a stop tap valve for the water is easily accessible We also recommend the use of a water block and non return valve to be fitted 2 We recommend that a filter is also fitted to ensure water of the highest quality A mounting bracket is provided inside the cabinet Always p...

Страница 5: ... power can be switched off when not using the fountain for an extended period of time e g more than 3 days to conserve energy However we recommend that the fountain is cleaned and at least 10 litres of water is flushed through upon switching on again for re use It may also be necessary to change the filter after an extended period of dis use 4 Keep the area surrounding the fountain clean and dry I...

Страница 6: ...e leaking Switch off power turn off water and call your service engineer Slow water flow The filter is blocked Change the filter No water dispenses from the taps Water inlet valve s closed or other blockage Open and or reset the water inlet valve s and or check water supply pipe Drainage waste blocked Debris has blocked up the waste system Clear the obstruction In the event of any other breakdown ...

Страница 7: ...t contact with water spray or splashing Avoid positions of direct sunlight or solar heat Be sure to use single outlet socket with correct power voltage Plug the power cord directly into the electrical socket 3 Allow an air gap of at least 100mm on each side and at the front of the machine 100mm 1 ...

Страница 8: ...cted from electricity before carrying out any maintenance work Turn off the water supply 1 2 3 To drain the Direct Chill tank remove the cap at the bottom of the tank This is located behind the front panel We recommend it is refitted immediately upon draining being completed ...

Отзывы: