818 Sport Models
26
No Water Dispenses continued
From Ambient
or Cold Valve
Button not being pressed
enough
Press button firmly N.B. This could be
caused by a surrounding cold environment
making the action stiffer
Faulty PCB
Replace PCB
From Sparkling
Valve
Firstly as for Ambient and
or Cold Dispense
Carry out the checks and actions as for
Ambient Dispense
Low or no CO
2
Check and replace cylinder as necessary
Pump not operating
Check carbonator level Control Systems
Check probes connected/leads attached.
Check power supply to pump
Carbonator Tank over
pressurised with CO
2
Switch Sparkling System off, shut off CO
2
supply and release CO
2
from carbonator.
Switch Sparkling system on the check pump
operation. If normal Open CO
2
supply after
pump has stopped.