Repairs on electrical parts
Before calling the Technical Assistance Service
check that:
– The plug has not come out of the socket.
– The main switch in the home is on.
If necessary, have the appliance serviced by
qualified personnel.
Remove the plug from socket before disassem-
bling any part.
Replacement of feed cable
The feed cable must be in HO5 RR-F, with a
cross sectional area of 3x1 mm².
It can be replaced as follows:
– open the terminal board;
– connect the wires to their terminals:
N – L – Earth;
– secure the wire with the cable clamp;
– close the terminal board with screws;
N.B.:
After installa-
tion the lead must be
accessible.
Fig. 5
Gas burner
Gas
Working
Rate
Nozzle Ø
Rated
Reduced
pressure
1/100 mm
power
power
Small auxiliary
Liquid
G30
30 mbar
g/h 73
50
kW 1
kW 0,45
burner
Liquid
G31
37 mbar
g/h 90
50
kW 1
kW 0,45
Liquid
G30
50 mbar
g/h 121
43
kW 1
kW 0,45
Liquid
G31
50 mbar
g/h 121
43
kW 1
kW 0,45
Natural
G20
20 mbar
l/h 94
71
kW 1
kW 0,45
Natural
G25
25 mbar
l/h 110
72
kW 1
kW 0,45
Medium semi
Liquid
G30
30 mbar
g/h 127
65
kW 1,75
kW 0,45
fast burner
Liquid
G31
37 mbar
g/h 157
65
kW 1,75
kW 0,45
Liquid
G30
50 mbar
g/h 212
58
kW 1,75
kW 0,45
Liquid
G31
50 mbar
g/h 212
58
kW 1,75
kW 0,45
Natural
G20
20 mbar
l/h 158
96
kW 1,75
kW 0,45
Natural
G25
25 mbar
l/h 165
94
kW 1,75
kW 0,45
Big fast burner
Liquid
G30
30 mbar
g/h 218
85
kW 3
kW 0,85
Liquid
G31
37 mbar
g/h 269
85
kW 3
kW 0,85
Liquid
G30
50 mbar
g/h 363
75
kW 3
kW 0,85
Liquid
G31
50 mbar
g/h 363
75
kW 3
kW 0,85
Natural
G20
20 mbar
l/h 270
115
kW 3
kW 0,85
Natural
G25
25 mbar
l/h 292
121
kW 3
kW 0,85
Triple ring 3.3 kW
Liquid
G30
30 mbar
g/h 240
93
kW 3,3
kW 1,40
Liquid
G31
37 mbar
g/h 296
93
kW 3,3
kW 1,40
Liquid
G30
50 mbar
g/h 400
73
kW 3,3
kW 1,40
Liquid
G31
50 mbar
g/h 400
73
kW 3,3
kW 1,40
Natural
G20
20 mbar
l/h 328
124
kW 3,3
kW 1,40
Natural
G25
25 mbar
l/h 323
130
kW 3,3
kW 1,40
Dual
Liquid
G30
30 mbar
g/h 65
46
kW 0,9
kW 0,3
Liquid
G31
37 mbar
g/h 80
46
kW 0,9
kW 0,3
Liquid
G30
50 mbar
g/h 108
43
kW 0,9
kW 0,3
Liquid
G31
50 mbar
g/h 108
43
kW 0,9
kW 0,3
Natural
G20
20 mbar
l/h 85
72
kW 0,9
kW 0,3
Natural
G25
25 mbar
l/h 100
69
kW 0,9
kW 0,3
Liquid
G30
30 mbar
g/h 306
66
kW 4,2
kW 1,75
Liquid
G31
37 mbar
g/h 377
66
kW 4,2
kW 1,75
Liquid
G30
50 mbar
g/h 510
61
kW 4,2
kW 1,75
Liquid
G31
50 mbar
g/h 510
61
kW 4,2
kW 1,75
Natural
G20
20 mbar
l/h 400
102
kW 4,2
kW 1,75
Natural
G25
25 mbar
l/h 460
105
kW 4,2
kW 1,75
INT.
TOT.
Nozzle table