Installation of indoor unit

Step one: choosing installation location

Step two: install wall-mounting frame

rm it with the client.

1.

    plastic expansion particles in the holes.

1.

Step three: open piping hole

2.

Choose the position of piping hole according to the direction of outlet pipe. The

position of piping hole should be a little lower than the wall-mounted frame,

shown as below.

Open a piping hole with the diameter of Φ55 or Φ70 on the selected outlet pipe

position.In order to drain smoothly, slant the piping hole on the wall slightly

downward to the outdoor side with the gradient of 5-10°.

Hang the wall-mounting frame on the wall; adjust it in horizontal position with the

3. Fix the wall-mounting frame on the wall with tapping screws and then check

if the frame is firmly installed by pulling the frame.If the plastic expansion particle

is loose, please drill another fixing hole nearby.

Left

Wall

Right

Rear piping hole

Wall

Space

to the

wall

above

150mm

Space

to the

wall

above

150mm

Rear piping hole

18K 230V

Φ55mm(Φ2 1/4)

Φ70mm(Φ2 3/4)

Φ55

mm

(

Φ2 1/4

)

Φ70mm(Φ2 3/4

)

Level meter

12K  

115

V

Left

Wall

Right

Mark in the middle of it

Level meter

Rear piping hole

Wall

Space

to the

wall

above

150mm

Space

to the

wall

above

150mm

Rear piping hole

Φ55mm

2 1

/4)

Left

Wall

Φ55mm

(Φ2 1/4)

Right

Level meter

Rear piping hole

Wall

Space

to the

wall

above

150mm

Space

to the

wall

above

150mm

Rear piping hole

9K

  115

V

24K 230V

Left

Wall

Φ7

0mm

(

Φ2 3/4

)

Φ7

0mm

(

Φ2 3/4

)

Right

Mark in the middle of it

Level meter

Rear piping hole

Wall

Space

to the

wall

above

150mm

Space

to the

wall

above

150mm

Rear piping hole

Φ55mm

2 1

/4)

Φ55mm

2 1

/4)

(5.9in)

(5.9in)

(5.9in)

(5.9in)

(5.9in)

(5.9in)

(5.9in)

(5.9in)

Содержание brisa BRS09HPL1IA

Страница 1: ...r product For proper operation please read and keep this manual carefully If you have lost the Owner s Manual please contact the local agent or visit www borealintl com or sent email to borealsales bo...

Страница 2: ...BRS09HPL1IA...

Страница 3: ...for installation 29 Selection of installation location 29 Requirements for electric connection 30 Installation Installation of indoor unit 31 Check after installation 36 Test and operation Test operat...

Страница 4: ...jury or property loss is caused by the following reasons Indicates a hazardous situation that if not avoided will result in death or serious injury Indicates a hazardous situation that if not avoided...

Страница 5: ...pliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowl...

Страница 6: ...amage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not...

Страница 7: ...e neutral wire and any work related to electricity and safety Be sure to cut off the power supply before proceeding Including an circuit break with suitable capacity please Air Conditioner should be p...

Страница 8: ...nnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only Precautions WARNING wire which can t be used for other purposes The grounding resistance s...

Страница 9: ...her must be installed in the line For the air conditioner without plug an circuit break Select a location which is out of reach for children and For the air conditioner with plug the plug should be 5...

Страница 10: ...ns FCC STATEMENT accordance with the instructions may cause harmful harmful interference in a residential installation This undesired operation frequency energy and if not installed and used in Howeve...

Страница 11: ...h Industry Canada licence This equipment complies with FCC s and IC s RF radiation exposure limits set forth for an uncontrolled environment The antenna s used for this transmitter must be installed a...

Страница 12: ...nce de 20 cm s pare l appareil l exception du combin des utilisateurs avec ceux ci Les installateurs doivent s assurer qu une 8 Working temperature range Indoor side DB WB C F Outdoor side DB WB C F M...

Страница 13: ...content or position may be different from above graphics please refer to actual products panel aux button horizontal louver air outlet NOTICE Actual product may be different from above graphics please...

Страница 14: ...ome models For some models For some models For some models indicator heating temp indicator cooling indicator power indicator receiver window drying display For some models heating indicator temp indi...

Страница 15: ...on mode I feel WiFi This is a general remote controller Some models have this function while some do not Please refer to the actual models Buttons on remote controller Introduction for icons on displa...

Страница 16: ...neral use remote controller it could be used for the air conditioners with multifunction For some function which the model doesn t have if press the corresponding button on the remote controller that...

Страница 17: ...emote controller will change quickly On releasing button after setting is nished temperature indica tor on indoor unit will change accordingly Temperature can t be adjusted under It s Low fan speed un...

Страница 18: ...um angle When selecting air conditioner is blowing fan at xed position Horizontal louver will stop at the xed position When selecting air conditioner is blowing fan at xed angle Horizontal louver will...

Страница 19: ...bject of high temperature or low temperature in order to avoid detecting inaccurate ambient temperature T ON button T ON button can set the time for timer on After pressing this button icon disappears...

Страница 20: ...re to factory default setting 16 12 Introduction for buttons on remote controller Press this button to set clock time icon on remote controller will blink Press or button within 5s to set clock time E...

Страница 21: ...on indoor unit displays set temperature When selecting with remote controller temperature indicator on indoor unit displays indoor ambient temperature When selecting with remote controller temperatur...

Страница 22: ...P and CLOCK buttons simultaneously to start up or turn off 8 heating function When this function is started up and 8 will be shown on remote controller and the air conditioner keep the heating status...

Страница 23: ...ore than 8m and there should be no obstacles between them Signal may be interfered easily in the room where there is uorescent lamp or wireless telephone remote controller should be close to indoor un...

Страница 24: ...ommended to use a soft dry cloth or wet cloth to wipe it NOTICE Do not wash the air conditioner with water to avoid electric shock Turn off the air conditioner and disconnect the power before cleaning...

Страница 25: ...to Clean and maintenance panel cover tightly operation environment clean frequency can be increased WARNING the water below 45 to clean it and then put it in a shady and cool place to dry 21 Open pane...

Страница 26: ...nage pipe is damaged 1 Disconnect power supply Notice for recovery 1 Many packing materials are recyclable materials Please dispose them in appropriate recycling unit 2 If you want to dispose the air...

Страница 27: ...8m Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Remove obstacles Select proper angle and point the remote controller at the re ceiving window on indoor unit Ch...

Страница 28: ...r temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temp...

Страница 29: ...ess devices etc Disconnect power put back power and then turn on the unit again Water flowing noise Air conditioner is turned on or turned off just now The noise is the sound of refrigerant flowing in...

Страница 30: ...g the unit If not please It can be eliminated after restarting the unit If not please F0 Note service Malfunction analysis When below phenomenon occurs please turn off air conditioner and discon for s...

Страница 31: ...27 Installation dimension diagram At least 250cm At least 15cm At least 300cm Space to the ceiling Space to the obstruction At least 15cm Space to the wall Space to the wall At least 15cm...

Страница 32: ...y make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe If compressor starts running when stop valve is open and connection pipe is...

Страница 33: ...end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 12 Universal meter 13 Inner hexagon spanner 14 Measuring tape Note Please contact the local agent for installation Don t us...

Страница 34: ...er to avoid a hazard 8 The temperature of refrigerant circuit will be high please keep the interconnec tion cable away from the copper tube 9 The appliance shall be installed in accordance with nation...

Страница 35: ...tapping screws and then check if the frame is firmly installed by pulling the frame If the plastic expansion particle is loose please drill another fixing hole nearby Left Wall Right Rear piping hole...

Страница 36: ...with torque wrench cut off the hole When select leading out the pipe from left or right please cut off the corresponding hole on the bottom case left right 1 The pipe can be led out in the direction...

Страница 37: ...55 60 65 70 75 15 20 insulating pipe 1 Connect the drain hose to the outlet pipe of indoor unit 2 Bind the joint with tape outlet pipe drain hose drain hose tape outlet pipe drain hose insulating pip...

Страница 38: ...ak must be installed in the line The circuit break should be all pole parting and the contact parting distance should be more than 3mm 3 Remove the wire clip connect the power connection wire to the w...

Страница 39: ...eparately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom connection pipe drain hose band indoor power cord Step nine hang the...

Страница 40: ...amaging the parts Is there any obstruction in the air inlet Is the inlet and outlet of piping hole been covered and outlet heating capacity The dust and sundries caused during installation are removed...

Страница 41: ...t according to the requirement as shown in the table The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refri...

Страница 42: ...4a Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 12 16 19 22 2 9 52 or 12 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350...

Страница 43: ...ng pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the port with expander No...

Страница 44: ...Boreal International a Watsco Inc subsidiary borealsales borealintl com www borealintl com 10300 NW 19th St 105 Doral FL 33172 786 621 8250 66129935316...