Installation

www.bora.com

X

X

Shut off the gas supply if you determine that gas is 

escaping and ventilate the room.

X

X

Seal the point from which the gas is leaking.

X

X

Re-check all connections and the gas connection.

X

X

Repeat the leak test until all connections are tight.

X

X

Create a leak test record and give this to the user.

X

X

Switch on the main switch/automatic circuit breaker.

X

X

Start up the system (see the Operation section)

X

X

Check all the functions of the cooktop extractor and 

cooktop are working correctly.

X

X

Check the burner flame is working correctly, 

particularly when the cooktop extractor is in use.

4.14.3 Changing the gas type

INFO 

The burner nozzles, gas type and pressure may only 

be changed by a certified engineer or BORA service 

technician. He/she also assumes responsibility for 

the proper gas installation and commissioning.

X

X

Switch all appliances off.

X

X

Close the gas supply to the gas supply pipe.

X

X

Switch off the main switch/automatic circuit breaker.

X

X

Secure the main switch/automatic circuit breaker 

against being switched back on without permission.

X

X

Make sure the power to the appliance is disconnected.

Changing the gas burner nozzle in the gas 

burner

INFO 

The nozzles regulate the maximum gas throughflow 

for each burner and gas type/pressure.

INFO 

The gas cooktop is set by default to natural gas 

G20/20mbar (pre-assembled).

INFO 

Use only stamped and approved nozzles.

The stamp on the nozzles corresponds to the values in 

the nozzle table and can be found either on the top or 

side of the nozzles.

EU
Gas type/ 

gas pressure mbar

Ø SR burner/

normal burner

Ø R burner/ 

high-power burner

G20/20

104

125

G25/20

110

131

G20/10

122

155

G20/13

115

149

G25/25  

G25.3/25

104

131

G20/25

100

119

G30/29 

G31/37

69

85

G30/50 

G30/31 – 50 mbar

62

78

Tab. 4.9  Nozzle table

Total nominal connection values for liquid gas:

Gas type

mbar

kW

g/h

m³/h

G30/G31

50

4.90

328

0.129

G30

29

5.00

348

0.137

Tab. 4.10  Liquid gas nominal connection values

Total nominal connection values for natural gas:

Gas type

mbar

kW

m³/h

G20

20

5.00

0.449

G25

25

5.10

0.538

G25.3

25

5.10

0.538

G20

13

5.10

0.486

G25

20

4.80

0.501

Tab. 4.11  Natural gas nominal connection values

1

2

3

4

5

6

Fig. 4.45  Gas burner structure

[1] 

Burner cap

[2] 

Burner head

[3] 

Electric igniter

[4] 

Safety thermocouple

[5] 

Burner housing

[6] 

Gas burner nozzle

X

X

Remove the pan support.

X

X

Remove the burner cap [1] from the burner head [2].

X

X

Remove the burner head [2] from the gas outlet.

Содержание Classic CKCB

Страница 1: ...EN C2XIMEN 004 www bora com BORA Classic 2 0 system installation instructions Cooktop extractor and cooktops...

Страница 2: ...ontents are prohibited unless expressly authorised Great care was taken when devising these operating and installation instructions However it may be the case that later technical changes or adaptatio...

Страница 3: ...on dimensions 23 4 7 Installation options 24 4 8 Assembling the extraction system 25 4 8 1 Assembling cooktop extractor CKA2 25 4 9 Installing the cooktop extractor 25 4 9 1 Fitting and positioning th...

Страница 4: ...regulations and laws All safety and warning information as well as the handling instructions in the operating and installation instructions must be observed 1 2 Validity INFO These instructions descr...

Страница 5: ...asised with symbols and signal words Safety and warning instructions are structured as follows WARNING SYMBOL AND SIGNAL WORD Type and source of danger Results of non compliance X X Measures to minimi...

Страница 6: ...use the appliance until installation is complete This is the only way to ensure safe operation X X Make sure contact with hot cooking surfaces is not possible X X Do not place any objects on the oper...

Страница 7: ...iately DANGER Risk of asphyxiation Packaging components e g film polystyrene can be life threatening for children X X Store all packaging components out of reach of children X X Dispose of the packagi...

Страница 8: ...erating unit can lead to a short circuit X X Do not operate any appliance with a damaged operating unit X X Inform a BORA Service technician and have the operating unit replaced Special safety informa...

Страница 9: ...burners on the cooktop is reduced The appliance is solely intended for preparing food in private households This appliance is not intended for Q Q outdoor use Q Q installation in vehicles Q Q heating...

Страница 10: ...x 190 mm Weight incl accessories packaging 7 5 kg Surface material SSG glass 1 4301 stainless steel and plastic Cooktop extractor Power levels 1 5 P Connection on the exhaust side BORA Ecotube Tab 3 1...

Страница 11: ...Fuse protection 1 x 16 A Dimensions width x depth x height 327 x 515 x 58 mm Weight incl accessories packaging 7 9 kg Cooktop Power levels 1 9 P Warming levels 3 Front cooking zone zone 1 power settin...

Страница 12: ...Power consumption 3 68 kW Fuse protection 1 x 16 A Dimensions width x depth x height 327 x 515 x 58 mm Weight incl accessories packaging 7 6 kg Cooktop Power levels 1 9 P Warming levels 3 Front cooki...

Страница 13: ...90 450 32 5 Fig 3 13 CKIW device dimensions side view 3 4 CKIW Parameter Value Supply voltage 220 240 V Frequency 50 60 Hz Power consumption 3 0 kW Fuse protection 1 x 16 A Dimensions width x depth x...

Страница 14: ...consumption 3 68 kW Fuse protection 1 x 16 A Dimensions width x depth x height 327 x 515 x 75 mm Weight incl accessories packaging 7 2 kg Cooktop Power levels 1 9 P 2 ring additional switching Warming...

Страница 15: ...ion 1 x 16 A Dimensions width x depth x height 327 x 515 x 75 mm Weight incl accessories packaging 7 4 kg Cooktop Power levels 1 9 2 ring connection roaster cooking zone connection Warming levels 3 Fr...

Страница 16: ...s width x depth x height cooktop pan support high power burner pan support normal burner 327 x 515 x 73 mm 270 x 270 x 25 50 mm 235 x 235 x 25 50 mm Weight incl accessories packaging 11 5 kg Cooktop P...

Страница 17: ...g Cooktop Temperature control power levels 150 230 C 250 C 1 9 P Warming levels 3 Front cooking zone zone 1 250 x 220 mm 1750 W Rear cooking zone zone 2 250 x 220 mm 1750 W Temperature control range 7...

Страница 18: ...ir in the room INFO The state and regional laws and regulations must be observed with regard to the exhaust duct design INFO A sufficient air supply must be ensured Fireplaces that depend on the air i...

Страница 19: ...n units of the base cabinet must be shortened depending on the installation situation X X Do not under any circumstances install parts which are damaged X X Dispose of transport packaging in the prope...

Страница 20: ...INFO The stopcock and gas supply pipe connections must be accessible INFO It must be possible to inspect the entire length of the hose line once installed INFO Only compatible connection pieces are t...

Страница 21: ...7 Worktop overhang X X Please note the worktop overhang x when creating the worktop cut out Applies to flush installation and surface mounting INFO The hose line must not come into contact with hot s...

Страница 22: ...25 Tab 4 4 Cut out dimensions of the appliance combinations in the case of surface mounting 4 5 1 Flush installation x A 2 B 2 519 2 R 5 R 5 50 50 495 2 600 Fig 4 8 Cut out dimensions for flush instal...

Страница 23: ...unit depth of 600 mm min 100 max 580 495 min 700 min 50 max 440 530 219 151 min 900 190 290 120 Fig 4 15 Appliance installation dimensions with shallow silencer USDF in case of a unit depth of 700 mm...

Страница 24: ...on options It is necessary to decide which installation option is to be implemented prior to installation X X Please ensure prior to installation that you have made the correct preparations for the co...

Страница 25: ...the adapter panel has been fitted correctly by looking at the arrow markings on the panel and the base module These must be correctly aligned Assembling the individual components 3 2 1 Fig 4 21 Assemb...

Страница 26: ...actor free of load and with the power supply switched off INFO Please bear in mind that for correct installation the slide in units of the base cabinet can be shortened depending on the installation s...

Страница 27: ...ction you can vary the height at which the sealing tape is attached to the plinth fan inlet nozzle INFO If another Universal fan module is to be used this must also be prepared as described here with...

Страница 28: ...Ensure that a minimum clearance of 3 m is maintained between the fan units X X Use only BORA Universal fans If additional fans are installed at a later date X X When installing additional fans at a l...

Страница 29: ...actor 1 Tensioning screw 2 Fixing bracket X X Turn the four fixing brackets 2 under the worktop Q Q The fixing brackets are secured against slipping by a ratchet mechanism X X Tighten the tensioning s...

Страница 30: ...ed Contact Function Connection Home In Cooktop extractor on off connection for external switch contact contact closed cooktop extractor on 24V DC 100 mA Home Out Electrically isolated contact for cont...

Страница 31: ...ase adhere to the maximum stripping length of the outer sheath of 25 mm on the insulated wire 2 Installing the external switch device Depending on the type of switch device connect the connection cabl...

Страница 32: ...nection diagram for cooktop extractor CKA2 1 Cooktop mains cable 2 Power supply per cooktop 3 CAT 5e communication cable 4 CAT 5e cooktop communication cable 5 USB interface 6 Control unit mains cable...

Страница 33: ...cable and mains cable it does not matter if you use socket 1 or 2 on the control unit 4 13 5 Positioning the control unit INFO The control unit must be placed inside the kitchen unit INFO Position th...

Страница 34: ...appliance 4 14 2 Gas connection This gas cooking appliance corresponds to device class 3 It is equipped with a flexible connection tube The gas hose must meet the requirements of EN14800 Q Q The insta...

Страница 35: ...o the appliance is disconnected Changing the gas burner nozzle in the gas burner INFO The nozzles regulate the maximum gas throughflow for each burner and gas type pressure INFO The gas cooktop is set...

Страница 36: ...on on the gas configuration menu can be seen in the operating instructions X X Enter the settings in the gas configuration menu see operating instructions Extended menu chapter 4 15 Initial operation...

Страница 37: ...lts when using gas cooktop CKG for the first time When operating for the first time or after a prolonged period without use or when the liquid gas bottles have been changed faults are possible Q Q The...

Страница 38: ...r Environmentally friendly disposal 5 3 Environmentally friendly disposal Disposal of transport packaging INFO The packaging protects the device from damage in transport The packaging materials have b...

Страница 39: ......

Страница 40: ...dorf Austria Tel 43 0 5373 62250 0 Fax 43 0 5373 62250 90 mail bora com www bora com Europe BORA Holding GmbH Innstra e 1 6342 Niederndorf Austria Tel 43 0 5373 62250 0 Fax 43 0 5373 62250 90 mail bor...

Отзывы: