EN
35
Installation
www.bora.com
X
X
Shut off the gas supply if you determine that gas is
escaping and ventilate the room.
X
X
Seal the point from which the gas is leaking.
X
X
Re-check all connections and the gas connection.
X
X
Repeat the leak test until all connections are tight.
X
X
Create a leak test record and give this to the user.
X
X
Switch on the main switch/automatic circuit breaker.
X
X
Start up the system (see the Operation section)
X
X
Check all the functions of the cooktop extractor and
cooktop are working correctly.
X
X
Check the burner flame is working correctly,
particularly when the cooktop extractor is in use.
4.14.3 Changing the gas type
INFO
The burner nozzles, gas type and pressure may only
be changed by a certified engineer or BORA service
technician. He/she also assumes responsibility for
the proper gas installation and commissioning.
X
X
Switch all appliances off.
X
X
Close the gas supply to the gas supply pipe.
X
X
Switch off the main switch/automatic circuit breaker.
X
X
Secure the main switch/automatic circuit breaker
against being switched back on without permission.
X
X
Make sure the power to the appliance is disconnected.
Changing the gas burner nozzle in the gas
burner
INFO
The nozzles regulate the maximum gas throughflow
for each burner and gas type/pressure.
INFO
The gas cooktop is set by default to natural gas
G20/20mbar (pre-assembled).
INFO
Use only stamped and approved nozzles.
The stamp on the nozzles corresponds to the values in
the nozzle table and can be found either on the top or
side of the nozzles.
EU
Gas type/
gas pressure mbar
Ø SR burner/
normal burner
Ø R burner/
high-power burner
G20/20
104
125
G25/20
110
131
G20/10
122
155
G20/13
115
149
G25/25
G25.3/25
104
131
G20/25
100
119
G30/29
G31/37
69
85
G30/50
G30/31 – 50 mbar
62
78
Tab. 4.9 Nozzle table
Total nominal connection values for liquid gas:
Gas type
mbar
kW
g/h
m³/h
G30/G31
50
4.90
328
0.129
G30
29
5.00
348
0.137
Tab. 4.10 Liquid gas nominal connection values
Total nominal connection values for natural gas:
Gas type
mbar
kW
m³/h
G20
20
5.00
0.449
G25
25
5.10
0.538
G25.3
25
5.10
0.538
G20
13
5.10
0.486
G25
20
4.80
0.501
Tab. 4.11 Natural gas nominal connection values
1
2
3
4
5
6
Fig. 4.45 Gas burner structure
[1]
Burner cap
[2]
Burner head
[3]
Electric igniter
[4]
Safety thermocouple
[5]
Burner housing
[6]
Gas burner nozzle
X
X
Remove the pan support.
X
X
Remove the burner cap [1] from the burner head [2].
X
X
Remove the burner head [2] from the gas outlet.