![bora Classic CKCB Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/bora/classic-ckcb/classic-ckcb_installation-instructions-manual_2788242021.webp)
EN
21
Installation
www.bora.com
2
1
Fig. 4.6
Plinth area air supply
[1]
Optional cable protection (shortened)
[2]
Air supply via the plinth area (opening cross-section ≥
150 cm²)
INFO
To ensure a sufficient air supply, an opening
cross-section of at least 50 cm² is recommended
in the front of the kitchen unit, or an opening
cross-section of at least 150 cm² in the plinth
area.
X
X
Make sure that the area below the cooktop has a
sufficient air supply.
4.5 Cut-out dimensions
INFO
All dimensions from the front edge of the front
cover.
Worktop overhang
≥50
x
Fig. 4.7
Worktop overhang
X
X
Please note the worktop overhang x when creating
the worktop cut-out. Applies to flush installation and
surface mounting.
INFO
The hose line must not come into contact with hot
surfaces on the cooktop or other devices.
INFO
The gas hose must be inspected every 5 years
and replaced if necessary. The gas hose must
meet the requirements of EN14800.
INFO
If the gas cooktop is used in a model with two
cooktop extractors, it is to be installed at the side.
If installed between the cooktop extractors, the
pull of air on both sides may affect the flames.
Air supply to gas cooktop CKG
1
2
Fig. 4.5
Air supply at front of the body
[1]
Air supply via the front of the body (opening cross-section
≥ 50 cm²)
[2]
Optional cable protection (shortened)