![bora Classic CKCB Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/bora/classic-ckcb/classic-ckcb_installation-instructions-manual_2788242034.webp)
EN
34
Installation
www.bora.com
Cooktop power connection
The mains cable to be used (pre-assembled) must be at
least Type H05V2V2-F.
Connection
Fuse protection Minimum cross-section
1-phase connection 1 x 16 A
1.5 mm
²
Tab. 4.7 Fuse protection and minimum cross-section
INFO
A damaged mains cable must be replaced by another
suitable mains cable. This may only be done by an
authorised member of the After Sales Service team.
X
X
Switch off the main switch/automatic circuit breaker
before connecting the cooktop.
X
X
Secure the main switch/automatic circuit breaker
against being switched back on without permission.
X
X
Make sure the power to the appliance is disconnected.
X
X
Only connect the cooktop using a fixed mains
connection.
1
L1
2
N
PE
220 - 240 V~
Fig. 4.44 Connection diagram 1-phase connection cooktop
Connecting the control unit to the power
supply
X
X
Connect the mains cable for the control unit to the
mains.
X
X
Check that installation has been carried out correctly.
X
X
Switch on the main switch/automatic circuit breaker.
4.14 Gas installation (only in the case
of gas cooktop CKG)
The gas connection may only be carried out by an authorised
gas fitter in accordance with applicable legal and local
regulations. Comply with local utility company regulations.
Country
Regulation/guidelines
Germany
DVGW TRGI 2018 and DVGW-worksheet G 600
Austria
ÖVGW-GK guidelines
Switzerland SVGW Gas Regulations G1
EKAA guideline 6517
Regulations of the Vereinigung Kantonaler
Feuerversicherungen (VKF)
Netherlands
Belgium
France
Regulations of standard NBN D 51-003
Regulations and connection requirements of the
gas supply company (G.D.F.) and electricity supply
company (E.D.F)
Tab. 4.8 Country requirements (information supplied without
liability)
4.14.1 Ventilation
This appliance is not connected to a flue gas evacuation
device. It must be positioned and connected in accordance
with the applicable installation conditions. Suitable
ventilation measures must be adhered to in particular.
X
X
Always ensure sufficient ventilation during operation
(of the appliance).
4.14.2 Gas connection
This gas cooking appliance corresponds to device class
3. It is equipped with a flexible connection tube. The gas
hose must meet the requirements of EN14800.
Q
Q
The installation of a gas bayonet socket in the adjacent
unit is recommended.
Q
Q
The connection of liquid gas (LPG) is performed with
the interconnection of a sealed connection socket
(pipe D: 8 x 1 mm).
Q
Q
The connection to the gas supply is to be created with
flexible and seamless pipes made from stainless steel.
Q
Q
The connection with a bayonet hose is to be created in
accordance with DIN 3383 with a maximum length of
1500 mm.
Q
Q
The connection bracket and connection pieces must
be equipped with a 1/2 inch external thread in
accordance with the regulatory country requirements
(see table 4.8).
X
X
Connect the appliance as follows:
X
X
Switch all appliances off.
X
X
Close the gas supply.
X
X
Switch off the main switch/automatic circuit breaker
before connecting the cooktop.
X
X
Secure the main switch/automatic circuit breaker
against being switched back on without permission.
X
X
Make sure the power to the appliance is disconnected.
X
X
Check the gas type and gas pressure of the gas supply
pipe.
X
X
Ensure that the appliance is equipped with the correct
nozzle type in order to guarantee a correct burner
flame and safe operation.
X
X
Remove the protective cap from the connection tube.
X
X
Use a bayonet socket to connect this directly to the
connection of the gas cooktop using a permitted hose
clip to prevent any leakage of gas.
Q
Q
Only use the connection permitted in your country.
Q
Q
ISO 228-1/ISO7-1(EN10226): cylindrical/conical
Q
Q
ISO 228-1/ISO 228-1: cylindrical/cylindrical
X
X
Connect the appliance to the gas supply pipe.
X
X
Tighten all connections so that they are secure.
X
X
Check that installation has been carried out correctly.
X
X
Check the correct functioning of the stopcock.
X
X
Check the tightness of the gas connection by
conducting a leak test.
X
X
Ensure that there is no risk of ignition sparks.
X
X
Do not use fire or an open flame.
X
X
Use suitable testing equipment to check all the
connections between the cooktop and the gas connection.
X
X
When using a leak spray for this process, ensure that
you wet all connections.