background image

EN

40

Cleaning and  maintenance

www.bora.com

X

X

Remove the activated charcoal filter by moving it 

downwards.

X

X

Dispose of used activated charcoal filters with house-

hold waste.

Inserting the activated charcoal filter

2

1

Fig. 8.9 

Inserting the activated charcoal filter

[1] 

Filter bracket

[2] 

Activated charcoal filter

X

X

Position the new activated charcoal filter [2] in such a 

way that the directional arrow is pointing to the rear 

and is visible from below.

X

X

Move the activated charcoal filter into the housing.

X

X

Press the activated charcoal filter upwards until the 

filter retainer [1] engages.

1

1

1

2

click

click

click

Fig. 8.10  Closing the activated charcoal filter housing lid

[1] 

Locks 

[2] 

Activated carbon filter housing cover

X

X

Fold the activated charcoal filter housing lid [2] by 

moving up upwards.

X

X

Press on the activated charcoal filter housing lid until 

the locks [1] engage.

Removing the activated carbon filter

1

Fig. 8.6 

Opening middle lock

[1] 

Lock, middle

X

X

Open the lock [1] in the middle.

1

Fig. 8.7 

Opening outer locks

[1] 

Outer lock

X

X

Open both outer locks [1].

X

X

Fold the lid (Fig. 7.5; [2]) down until it engages.

2

1

Fig. 8.8 

Removing the activated carbon filter

[1] 

Activated charcoal filter

[2] 

Filter bracket

X

X

Hold the activated charcoal filter with one hand [1].

X

X

Push the filter retainer [2] to the back.

Содержание BFIA

Страница 1: ...EN BFIASUMEN 003 www bora com Operating and installation instructions BFIA BFIU Surface induction glass ceramic cooktop with cooktop extractor M8800406 000...

Страница 2: ...of its contents are prohibited unless expressly authorised These operating and installation instructions have been drawn up with the greatest of care But it cannot be ruled out that subsequent techni...

Страница 3: ...Selecting the power setting 32 7 2 5 Switching the power setting off early 32 7 2 6 Switching off the cooking zone 32 7 2 7 Pay attention to the residual heat display 32 7 2 8 Pause function 33 7 2 9...

Страница 4: ...nd commissioning Gas specialists The gas connection may only be established by certified engineers They also assume responsibility for proper installation and commissioning of the gas system Tab 1 1 T...

Страница 5: ...hted with symbols and signal words Safety and warning information is structured as follows WARNING SYMBOL AND SIGNAL WORD Type and source of the danger Consequences of non compliance X X Measures to m...

Страница 6: ...Make sure that hot hobs are not touched X X Avoid boiling over X X Pay attention to the residual heat display X X Switch the device off after use X X Do not rely on the pan size recognition X X Keep p...

Страница 7: ...e and cause serious injury X X Do not place any flammable liquids in the vicinity of the cooktop Households with children and people with special needs X X The appliance can be used by children aged 8...

Страница 8: ...cooking sessions must be constantly monitored DANGER Risk of electric shock Chips cracks or breaks in the glass ceramic panel can expose or damage the electronics underneath This can lead to an elect...

Страница 9: ...of smoke inhalation Using a fireplace that depends on the air in the room produces combustion gases If the cooktop extractor is used in conjunction with a fireplace that depends on the air in the roo...

Страница 10: ...all damaged devices Q Q A damaged device is a hazard Q Q Repair work must only be carried out by specialists authorised by the manufacturer 2 3 Safety instructions installation The device must only be...

Страница 11: ...ctions disassembly and disposal The device must only be disassembled by trained specialists who are familiar with and comply with the standard national regulations and supplementary regulations of the...

Страница 12: ...0 W Power levels 1 9 power setting Cooktop energy consumption Cooking zone 1 182 2 Wh kg Cooking zone 2 181 1 Wh kg Cooking zone 3 182 2 Wh kg Cooking zone 4 181 1 Wh kg Total average 181 65 Wh kg Ext...

Страница 13: ...3 m h 658 8 m h 61591 Sound power level Level 1 minimum 40 dB A 39 dB A 60704 2 13 Level 9 normal 66 dB A 67 dB A 60704 2 13 Level P maximum 70 dB A 70 dB A 60704 2 13 Sound pressure level additional...

Страница 14: ...of rooms where fireplaces are installed If the exhaust air is to be directed into a smoke or exhaust gas flue that is not in use the installation must be checked and approved by the responsible heati...

Страница 15: ...matic heat up function L Childproofing feature Bridging function I I Break Heat retention level 42 C Heat retention level 74 C Heat retention level 94 C v No cookware or cookware is too small H Residu...

Страница 16: ...buttons a setting field and display panels The sensor buttons respond to finger contact You operate the device by touching the corresponding sensor button with your finger Keep the finger pressed on...

Страница 17: ...s Extractor level 4 4 4 4 5 6 7 8 9 P Cooking level 1 2 3 4 5 6 7 8 9 P Tab 5 6 Extraction performance and cooking level Q Q If the power level of the cooking zones is changed the automatic cooktop ex...

Страница 18: ...all cooking zones are switched off see the Operation chapter 5 4 3 Power setting The cooktop extractor has a power enhancing power setting This power setting makes it possible to suction away high lev...

Страница 19: ...If there are any missing or damaged parts please noti fy BORA After Sales Service immediately X X Do not under any circumstances install parts which are damaged X X Dispose of transport packaging in t...

Страница 20: ...X X Precisely align the cooktop Q Q Cross bars on the kitchen unit in the area of the worktop cut out may need to be removed Q Q No false floor is necessary below the cooktop with cooktop extractor Q...

Страница 21: ...justment plate X X If applicable insert the height adjustment plate 2 X X Note down the type designation and build number of the cooktop FD number on the back of this manual Both details can be found...

Страница 22: ...1 from below Q Q A minimum clearance of 25 mm between the back furniture body wall and an adjacent kitchen unit or room wall must be observed for the return flow aperture Preparing the back wall of t...

Страница 23: ...t click 1 4 3 2 Fig 6 16 Mounting the frame of the flexible duct 1 Retaining groove of the housing of the activated charcoal filter 2 Position shackles 3 Flexible duct frame 4 Lower lock X X Insert th...

Страница 24: ...om in which they are installed and release the exhaust fumes into the outside air via an exhaust system e g chimney If the cooktop extractor is used in exhaust mode it draws in air from the room in wh...

Страница 25: ...ic panel facing downward on a clean and soft surface e g cardboard packaging material in order to avoid damage to the glass ceramic panel 3 2 1 Fig 6 25 Removing the housing base 1 Housing base 2 Lock...

Страница 26: ...g 2 upward 3 2 1 Fig 6 30 Inserting the air duct extension 1 Exhaust air arc 2 Exhaust air duct extension 3 Air guiding housing 1 1 1 Fig 6 26 Unlocking the position lock 1 Shackles for position lock...

Страница 27: ...ion X X Hold the suction opening 2 X X Insert the cooktop in the middle of the worktop cut out 5 X X Insert the exhaust air duct extension 2 into the groove of the air guiding housing 3 X X Insert the...

Страница 28: ...6 Connection diagram 3 phase connection 1 L1 L3 2 3 4 N PE 220 240 V 220 240 V Fig 6 37 Connection diagram 2 phase connection 1 L1 2 3 4 N PE 220 240 V Fig 6 38 Connection diagram 1 phase connection F...

Страница 29: ...e Out communication connection must only be connected by a certified specialist He she also assumes responsibility for the proper installation and commissioning 4 4 1 1 3 2 Fig 6 39 Electrical connect...

Страница 30: ...e In and Home Out you will require the relevant documents for the external switching devices in order to ensure safe device connection and operation The following switch connections can be used Contac...

Страница 31: ...the cover 1 X X Tighten the cable tie 4 tension relief X X Ensure that the cable is not caught or damaged and is not able to touch any hot hobs X X Verify that the installation was done correctly X X...

Страница 32: ...e desired power level or X X Press and uniformly swipe round the setting ring until the desired power level is reached 7 2 3 Changing the power level X X Press the cooking zone button for the desired...

Страница 33: ...ng level set for example 5 Changing the automatic heat up function The power level of the continuous cooking level can be changed within 15 seconds of activation X X Select the cooking zone X X Select...

Страница 34: ...t off X X Press the timer button multiple times to increase the duration by 10 minutes each time X X Change the minutes in the timer display by uniformly swiping the setting ring 7 2 13 Switching off...

Страница 35: ...etting P Q Q The power setting P is displayed in the cooking zone indicator Q Q The power setting P automatically switches to power level 9 after 10 minutes 7 3 5 Automatic cooktop extractor function...

Страница 36: ...actor function is activated Q Q A appears on the display 7 3 6 Switching off the automatic cooktop extractor function X X Press the selection button for the cooktop extractor X X Press the multi funct...

Страница 37: ...use any aggressive acidic or alkaline cleaning agents 8 2 Maintaining the cooktop X X Do not use the cooktop as a worktop or shelf X X Do not push or pull cookware across the cooktop X X Always lift...

Страница 38: ...air guiding housing Greasy deposits and limescale residues from the cooking vapour can accumulate on the surface of the air guiding housing Regular thorough cleaning see Table 7 1 is thus necessary T...

Страница 39: ...fan level indicator indicates F filter service display BAKF activated charcoal filters can be pur chased from your specialist You can also contact BORA on its homepage http www bora com X X Make sure...

Страница 40: ...rds until the filter retainer 1 engages 1 1 1 2 click click click Fig 8 10 Closing the activated charcoal filter housing lid 1 Locks 2 Activated carbon filter housing cover X X Fold the activated char...

Страница 41: ...Clean the operating panel or remove objects see the Device description chapter The cooling fan continues running after the cooktop has been switched off The cooling fan will continue to run until the...

Страница 42: ...ndly disposal 10 3 Environmentally friendly disposal Disposal of transport packaging INFO The packaging protects the device from damage in transport The packaging materials have been selected from env...

Страница 43: ...you are not able to resolve yourself please contact your BORA specialist supplier or the BORA Service Team The BORA Service Team requires the type designation and the build number of your appliance FD...

Страница 44: ...Austria T 43 0 5373 62250 0 F 43 0 5373 62250 90 mail bora com www bora com Europe BORA Holding GmbH Prof Dr Anton Kathrein Stra e 3 6342 Niederndorf Austria T 43 0 5373 62250 0 F 43 0 5373 62250 90...

Отзывы: