Replacement Parts 

 

Description

 

Part No 

2 Stage Pump 

3B3718 

3 Stage Pump 

3B3719 

4 Stage Pump 

3B4384 

Mechanical Thermostat 

1A4769 

Eliwell Thermostat 

1A5100 

DFx Thermostat 

3B5544 

Fan motor 

3B3496 

 

Removal, Transportation and Disposal

 

Important: Before removal from the installation, ensure all electrical, product and gas

 

connections are disconnected.

 

 

Disposal of Scrap Units 

 

It  is  illegal  to  simply  scrap  a  refrigeration  unit.  Before  a  unit  can  be  scrapped  it  must  first  have  the 
gas  removed  by  a  specialist  using  special  equipment.  Please  contact  Booth  Dispensers  Ltd.,  who 
will be happy to provide a quotation for disposal. 

 

Transportation

 

 

Important

: This unit must be transported in an upright position 

 
As with all refrigeration systems, irreparable damage can be caused by laying the unit on its side or 

even transporting upside down. Where the unit is transported by a carrier, the carton should always 
be marked in a conspicuous manner, the correct upright position in which it must be handled. 
 
If a unit has been transported  incorrectly it should  be placed in the correct upright position and  left 
for 24 hours before attempting to run the system. 
 
Failure  to  observe  the  above  precautions  could  seriously  damage  the  system,  and  would  void  any 
warranty. 

 

 
 
 

 

Booth Dispensers Ltd, Moor Park Avenue, Blackpool, 

Lancashire, FY2 0LZ, UK 

+44 1253 501800 

 

Replacement Parts, Removal, Transportation and Disposal 

 

 

Содержание BRW181E

Страница 1: ...Product Manual BRW18 Range Part Number 3B6555 Issue 01 19 12 15 ...

Страница 2: ...s are covered on the following pages as well as wiring schematics for the units fitted with the mechanical digital controllers Specification Dimensions approx 450mm W 485mm D 725mm H 2 Stage variants 745mm H 3 4 Stage variants 770mm H SCOPE variants Compressor SCOPE Variants Huyai Cubigel GPY16Lab Other models Danfoss FR11G Dry Weight Nominal 36 Kg will vary depending on unit type This product con...

Страница 3: ...duct coils 2 stage pump mechanical thermostat BRW186E 6 product coils 2 stage pump digital thermostat BRW187 6 product coils 3 stage pump mechanical thermostat BRW187E 6 product coils 3 stage pump digital thermostat Installation and Commissioning The unit must be installed by a competent person on a firm level surface capable of supporting the weight of the machine when the bath is filled and all ...

Страница 4: ...E N WH BU CONNECTOR BLOCK IEC SOCKET CONDENSOR FAN COMPRESSOR CONTROL THERMOSTAT NOTE SOME EARTH CABLES GN YE OMITTED FOR CLARITY BR G Y BU BR BR WH BU BU POWER ON INDICATOR BR BU Schematics Wiring for models with mechanical thermostat ...

Страница 5: ...with Eliwell thermostat Fuse BR L N MAINS PLUG G Y L NC E N WH BU CONNECTOR BLOCK IEC SOCKET CONDENSOR FAN COMPRESSOR ELIWELL THERMOSTAT NOTE SOME EARTH CABLES GN YE OMITTED FOR CLARITY BR G Y BU BR BR BU G Y BU BU 7 6 3 2 1 BR WH BU ...

Страница 6: ...atics Wiring for models with DFx thermostat Fuse BR L N MAINS PLUG L NC E N BR BU IEC SOCKET CONDENSOR FAN COMPRESSOR DFx THERMOSTAT NOTE SOME EARTH CABLES GN YE OMITTED FOR CLARITY G Y BU BU N L L2 C BR RD BR ...

Страница 7: ...e a quotation for disposal Transportation Important This unit must be transported in an upright position As with all refrigeration systems irreparable damage can be caused by laying the unit on its side or even transporting upside down Where the unit is transported by a carrier the carton should always be marked in a conspicuous manner the correct upright position in which it must be handled If a ...

Отзывы: