Page 3
3B-390977NI – 01/17
BONNET GRANDE CUISINE
Rue des Frères Lumière - Z.I Mitry Compans
77292 MITRY MORY Cedex
1.2
20 LEVEL OVENS AND TWIN CAVITY OVENS
The required height of the loading threshold is 355mm. The required height of the loading threshold is 275mm on 6+6 ovens and 325mm
on 6+10 ovens. The oven must be fixed to the floor using the two brackets supplied with the oven. Fit both brackets to the rear legs.
6.2
INSTRUCTION FOR HOT CONTAINERS
Maximal heigh for loading is 1600mm from the ground. A
sticker is delivered with the instructions manual. Place the sticker on
the Combi oven at 1600mm from the ground
Danger: For containers that are filled with liquid or food that
liquefies during the cooking process, operators must be
able to see the contents of the container if it is inserted
any higher.
7
INSTALLATION: CONNECTIONS
7.1
RACCORDEMENT ELECTRIQUE
The fixed electrical supply to the unit must incorporate an appropriate isolator that can be locked in the off position.
All aspects of the installation should be in compliance with current local regulations.
The appliance must be connected to the earth.
Les instructions doivent fournir les recommandations concernant les caractéristiques et le type des dispositifs de protection
supplémentaires à installer, tels qu'un ou des dispositifs à courant différentiel résiduel.
Electric connection is carried out from the at the rear of the
appliance on the right, whatever the model
- Remove the right hand panel.
- Pull the cable through the gland.
- Connect the wires (check the neutral and the earth).
- Tighten the gland.
- Refit the side panel.
- Connect the equipotential link to the terminal provided for
this purpose.
Location of the earth cross bonding terminal
•
Only use H07 RN-F type supply cable sized to suit the load of the unit as defined in the table below. (see chapter 1 « technical
characteristics » which give the electrical rating).
Provide an approved omnipolar isolation device, (with at least 3 mm clearance between the contacts).
Intensity (A)
Cable section (mm²)
Intensity (A)
Cable section (mm²)
0.1 to 16
2.5
40 to 63
10
16 to 25
4
63 to 96
16
25 to 40
6
96 to 127
25
Oven leg
Bracket