Page 9
3BE490017NU – 04/19
BONNET GRANDE CUISINE
Rue des Frères Lumière - Z.I Mitry Compans
F-77292 MITRY MORY Cedex
Too much chlorine in the mains water supply
Sometimes certain networks supply water containing chlorine at above normal levels. In this event it is not unusual to be faced with
problems of corrosion, pay particular attention to bain-marie, water baths, and equipment left to soak overnight etc.
Cleaning aluminium or aluminium coated items
The presence of aluminium or items that are aluminium coated in a chlorine solution is a particularly powerful catalyst for damaging
stainless steel. Do not leave fittings such as hood filters, aluminium trays or dishes soaking in wells, tanks, pots, fryers etc. Just one night is
sufficient to etch stainless steel at the point of contact with aluminium.
5.3 CLEANING STAINLESS STEEL SURFACES
It is necessary to keep the metal surface perfectly clean by removing all dust, metallic particles and deposits of any nature that could damage
the protective sheet as mentioned above.
To achieve this it is sufficient to wash these surfaces with water and soap or any neutral, non-abrasive detergent product. RINSE CAREFULLY
and wipe the surfaces dry.
Never scrub stainless steel with wire if necessary use a non-stick scourer or similar and scrub in the same direction as the stainless steels
polished finish.
5.4 GAS MAINTENANCE
To ensure long-lasting, safe and correct operation, we recommended a preventative maintenance service twice a year by qualified personnel
(Dismantling of burners, inspection and cleaning of venturis, cleaning of nozzles, adjustment of air rings, cleaning of vents, checking possible leaks,
checking control elements, regulating and safety accessories…).
IF CHANGING FROM ONE GAS TO ANOTHER USE A QUALFIED PROFFESSIONAL GAS ENGINEER.
6 RECOMMENDED AND FRONT LINE SPARE PARTS
Description
Code
Drilled and tapped bratt pan crank
132723
1 way 1 x 10 L/min solenoid valve
144937
Ram control cable sub assembly
156256
Micro switch sub assembly
156258
12 diameter black 4A 250V COSSE push-button
300157
230 V lever microswitch
300678
Three-pole 25A 230V 50/60 Hz contactor
300697
Three-pole 32A 230V 50/60 Hz contactor
300698
Three-pole 40A 230V 50/60 Hz contactor
300699
4 position switch
300770
60-280°c single pole thermostat
301031
Simmerstat
301200
2250 W element
302255
Black LINAK ram without slot
304274
Control pushbutton for tilting jack
307969
Red indicator 230/400V, complete
308010
Green indicator 230/400V, complete
308334
Ignition electrode M4
308480
2 point ignitor
308487
1 µF condensor
309554
Ram control box
309575
Pilot jet 40 diameter (K14)
310091
Pilot injector jet 55 diameter (NE22)
310154
Ignition box and flame monitor (Until 31
st
October 2018 N° P46413391R)
310197
Range 160 3 flame pilot burner without nut
310272
Pilot flame nozzle diameter 41
310273
Pilot flame nozzle diameter 25
310274
Range 200 thermocouple, length 850 mm
310276
Gas valve (Until 31
st
October 2018 N° P46413391R)
310305
Ignition and flame control box (From 1
th
November N° P46413392S)
310352
Sigma 840 Gas valve (From 1st November N° P46413392S)
310353
Gas tap
310328
Pilot flame nozzle diameter 45
311172
Metal cage ball thrust bearing (mandatory)
383310
Draw spring with 30 x 200 diameter stainless steel insert
385051