Bonica BC988 Скачать руководство пользователя страница 9

                     

  

      

 

      

     

      

  

 

        

       

     

– 7 –

-

Add a 100 gram weight on the outside in any angular position.

-

Press START .

-

The machine is calibrated at the end of the cycle. The display reads “END CAL”.

Remove the 100 gram weight from the wheel, which can now be balanced with a further cycle.

The values that the machine records form this self-calibration operation are automatically stored in a special memory which also
maintains them when the machine is switched off, with storage lasting for about 10 years, so the machine will be ready for
correct functioning every time it is switched on.
However, the self-calibration operation can be repeated as often as you like or whenever the correct functioning of the machine
is in doubt.

Plane and

 Used on Aluminum Alloy Wheels. Weight is to be applied on the Center

 clamped to the Outer Edge.

For balancing standard steel or alloy wheels using 

clip-on weights attached to inner and outer wheel edges.

(No Symbol Illuminated)

DYNAMIC

3.10 STATIC-ALU functions

:

ALU1

:For balancing of the light alloy rims with application of adhesive weights on the rim

shoulders

ALU2

: For balancing wheel rims in light alloy with application of the inner side adhesive

weight. Position of the inner side weight is the on shown in the figure

ALU3

:

Fig. 5

(For balancing wheels of motorcycle, in light alloy or special construction forms)

St

.: STATIC correction is required for motorcycle wheels or when it is not possible to place

the counterweights on both sides of the wheel rim.

Press key ALU to select the desired function. For each function, the microprocessor
elaborates the real values of the compensating weight corrected on the basis of the position
of the correction weight and memorizes them quickly on the unbalance displays.

-

3.11 Optimizing the unbalance

The optimizing operation enables you to reduce the amount of weight to add to the wheel in order to balance it. In many cases,

an improvement of the residual eccentricity on the tire can also be achieved.

-

Press key OPT, The display reads “r.S.”

-

Press START The machine runs a measuring cycle.

-

The display gives an instruction to turn the tire on the wheel rim. Make a reference mark on the adapter and wheel rim

with chalk, so as to be able to refit the wheel rim on the bead of the tire in the same position.

-

Use a tire changer to rotate the tire through 180 on the wheel rim.

-

Fit the wheel rim back onto the adapter in the same position as before.

-

Press START. The machine runs a second measuring cycle.

Содержание BC988

Страница 1: ...Wheel Balancer Operation Manual Model BC988 BONIC ...

Страница 2: ... WHEEL BALANCING 3 9 SELF CALIBRATION FACILITY 3 10STATIC ALU FUNCTIONS 3 11 OPTIMIZING THE UNBALANCE 3 12 INCONSTANT UNBALANCE READINGS 4 ORDINARY MAINTENANCE 8 4 1 ADJUSTING THE BELT PULLEY 4 2 COMPUTER BOARD REPLACEMENT 5 TROUBLE SHOOTING 9 6 LOGIC TROUBLE SHOOTING SEQUENCE 10 6 1 CHECKING AND SETTING OF STATIC VALUE STI 6 2 CHECKING AND UNBALANCING POSITION 6 3 CHECKING AND CALIBRATION OF FIXE...

Страница 3: ...ould only be used by specially trained and authorized personnel The training and informing of the operating staff should be done so as to enable them to operate the machine as described in the instructions provided by the manufacturer so that the machine performs in the best possible way and the operations are carried out efficiently and safely For any doubts relating to the use installation and m...

Страница 4: ... or other sticky materials on the flooring since this is a potential danger for the operator The operator must wear suitable work clothing protective goggles gloves and mask to prevent harm from dust or impurities being blown out Dangling objects such as bracelets should not be worn long hair should be protected in a suitable manner shoes should be suitable for the type of operation to be performe...

Страница 5: ...al data 3 Product Weight 165 35lbs 75kg 2 INTRODUCTION The wheel balancer with a microprocessor capable of balancing wheels weighing up to 45 Kg The control elements and signals are all contained on the front panel The keyboard calibration system also provides a sufficient adjustment range to cope with unusual wheels acing motorcycles and cars Some ALU functions are available for specially shaped ...

Страница 6: ...inches self calibrating 10 Emergency key 11 Key to start cycle 12 Opt program 3 INSTRCUTIONS FOR USE 3 1 Lifting and Installation Lever the base to lift the balancing machine In no circumstances should and force be applied to other parts such as the mandrel the headstock the casing or the accessories tray 3 2 Power supply Before connecting the machine to the mains with the cable provided check tha...

Страница 7: ...oard Varying the distance dimension A Varying the width dimension L Varying the diameter dimension D Recalculating the values Disp The values below the threshold Static Dynamic ALUx Dynamic Balancer self calibrating Start by closing the guard Unbalance measured in gm or oz Width measured in mm or inches Diameter measured in mm or inches Start measuring cycle Emergency cycle stop The unit of measur...

Страница 8: ...T An unbalance value reading below 10 12 grams 0 4 0 5 oz is normally sufficient for good balancing With this balancing machine it is easy to balance to a tolerance of only 5 grams 0 2 oz or less THRESHOLD KEY FINE The correction of residual unbalance below 5 grams 0 2 oz can be read whenever necessary wheels for special uses by pressing this key with the machine at a standstill Display 3 and 5 fo...

Страница 9: ...ion of the inner side adhesive weight Position of the inner side weight is the on shown in the figure ALU3 Fig 5 For balancing wheels of motorcycle in light alloy or special construction forms St STATIC correction is required for motorcycle wheels or when it is not possible to place the counterweights on both sides of the wheel rim Press key ALU to select the desired function For each function the...

Страница 10: ...ly or as often happens the holes in the wheel may have too much tolerance Small errors up to 10 grams 0 4 oz should be considered normal in wheels fitted on a cone adapter the error is normally greater for wheels fitted with screws or blocks If the wheel is found to be still unbalanced when it is fitted to the vehicle after balancing this depends on the unbalances in the vehicle s brake drums or v...

Страница 11: ...ten or replace the belt ERR 2 The rotation is lower than 60 min a Accidental breaking in rotation unit b Loose driving belt c No tire mounted or lower rotary speed a Check and eliminate the cause of breaking b Tighten or replace the belt c Mounted adequate tire ERR 3 Miscalculation a Incorrect self calibration b Too high unbalance c Faulty memory card a Repeat the self calibration b Check the corr...

Страница 12: ...When the computer board is replaced preset the machine parameters indicated on relative nameplate 6 1 CHECKING AND SETTING OF STATIC VALUE STI N Y Carry out self calibration Wheel balancing Tolerance 1 gram Select STATIC Apply 100 grams on inside Perform the spin Is the STATIC value on the inside between 98 and 102 grams Select function SELECTON OF MACHINE PARAMETERS Increase value 1 if the inside...

Страница 13: ...libration Wheel balancing Tolerance 1 gram Apply weight of 100 grams on the outside Perform the spin Is the 100 gram counterweight in the six o clock position Select function SELECTION OF MACHINE PARAMETERS Modify value S by making various attempts S is expressed in degrees END ...

Страница 14: ...low the procedure for CHECKING AND CALIBRATION DISTANCE VALUE DF 100 g weight on Inner Side F I the indication of dynamic unbalance is F I 100 5 F E 5 Select MACHINE PARAMETERS modify DF value by increasing or decreasing it 5 figures at a time Make self calibration END ...

Страница 15: ... 13 7 POWER SUPPLY LAOUT DIAGRAM 220 V CONNECTION ...