– 5 –
13. Threshold key
14. Key for selecting type of correction
15. Recalculation key
N.B. : Only use the fingers to press the push buttons. Never use the pincers for the counterweights or other
pointed objects
.
3.3 Fixing the adapter
Before fixing the adapter on the balancing machine shaft, check that the shaft and the adapter centering area are clean.
Use one of the many adapters produced as per catalogue.
Remember that imperfect centering provokes unbalances on use the wrench provided to block the adapter onto the balancing
machine shaft.
3.4 Mounting the wheel
Mounting the wheel with suitable cone and adjustable nut Remember that imperfect centering provokes unbalances
unnecessarily.
3.5 Using the keyboard
The following operations can be carried out using the keyboard:
Varying
the
distance
(dimension
“A”)---------------------------------------------------------------
Varying
the
width
(dimension
“L”)-------------------------------------------------------------------
Varying
the
diameter
(dimension:
“D”)-------------------------------------------------------------
Recalculating
the
values------------------------------------------------------------------------------
Disp.
The
values
below
the
threshold-------------------------------------------------------------
Static
Dynamic------------------------------------------------------------------------------------------
ALUx
Dynamic------------------------------------------------------------------------------------------
Balancer
self-calibrating------------------------------------------------------------------------------
Start
by
closing
the
guard-----------------------------------------------------------------------------
Unbalance
measured
in
gm
or
oz------------------------------------------------------------------
Width
measured
in
mm
or
inches-------------------------------------------------------------------
Diameter
measured
in
mm
or
inches--------------------------------------------------------------
Start
measuring
cycle----------------------------------------------------------------------------------
Emergency
cycle
stop----------------------------------------------------------------------------------
The
unit
of
measurement
chosen
for
the
unbalance
(grams
or
ounces)
or
by
pressing
the
START
key
are
stored
in
the
machine’s
memory
when
it
is
switched
off.
If
the
unit
of
measurement
selected
for
the
width
and
diameter
(mm
or
inches)
is
inches,
this
selection
must
be
repeated
every
time
the
machine
is
started
up.
3.6
Calibrating
the
panel
DIAMETER:
input
the
diameter
“d
“
which
is
shown
on
thetire.
WIDTH:
input
the
width
"b",
which
is
normally
shown
on
the
wheel
rim,
or
measure
the
width
“b”
with
the
calipers
↑
a
or
↓
a
↑
b
or
↓
b
↑
d
or
↓
d
C
FINE
F
ALU
F + C
F + STOP
F +
↑
a
+
↓
a
F +
↑
b
or F +
↓
b
F +
↑
d
or F +
↓
d
START
STOP
Fig. 3