![Bongioanni IDEA Series Скачать руководство пользователя страница 23](http://html.mh-extra.com/html/bongioanni/idea-series/idea-series_installation-and-servicing-instructions_2787067023.webp)
EDIZIONE 5/97
FLUE SAFETY THERMOSTAT
3.5
RE-STARTING THE BOILER
The activation of the flue safety thermostat is indicated by a red signal lamp on the control
facia corresponding to the symbol “chimney obstructed”.
To re-start the boiler proceed as follows:
-
turn off power supply
-
remove the casing front panel to reach the flue thermostat reset button
-
remove (unscrew) the plastic cover on the reset button
-
push down the red reset button
-
refit the plastic cover and re-assemble the casing front panel
-
turn on power supply.
WARNING: should the flue safety thermostat trip more than three times, it is abso-
lutely vital to call for a Qualified Service Engineer to check for the possible cause of
failure. Should the chimney draught be inadequate, then corrective action must be
taken.
PROHIBITION: the flue safety thermostat has been pre-setted and its sensor positioned
in such a way that the device will trip in accordance with the Regulations in force.
Therefore it is absolutely forbidden to change either the phial position or electrical con-
nection. It is also forbidden to replace the flue safety thermostat with another of non-origi-
nal supply.
17
Содержание IDEA Series
Страница 1: ...IDEA IDEAINSTALLATION A N D S ERV IC ING IN S T RU C TIONS tipo P ...
Страница 2: ......
Страница 6: ......
Страница 11: ...1 6 1 EXPLODED VIEW OF BOILER BLOCK unaccesoried version EXPLODED DRAWINGS AND PARTS LIST 1 6 5 ...
Страница 13: ...1 6 3 EXPLODED VIEW OF BOILER BLOCK accesoried version 7 ...
Страница 24: ...12010 VIGNOLO CN Via Cervasca 6 TEL 0171 407111 TELEX 226662 SARB I FAX 0171 407350 ...