background image

C

onnect 

H

ose 

&

 Regulator to 

C

ylinder

20LB Propane Cylinder 

307.9 mm

S

tep 

1

 - Gas 

C

ylinder Required

You

 must provide propane gas and propane cylinder.

Use a standard 20lb propane cylinder only.

Use this heater only with a propane vapor withdrawal
supply system. See chapter 5 of the Standard for 

Storage 

and Handling of Liquefied Petroleum Gas, ANSI/ NFPA 58. 
Your local library or fire department will have this book.
Maximum supply pressure of 250 psi. A mini

m

um supply 

pressure of 

25 psi

 is required for the purpose of input 

adjustment for propane gas.
The pre

s

sure regulator and hose assembly supplied with 

the appliance must be used

. Replacement pressure regu

-

lators and hose assemblies must be those specified by the 
appliance manufacturer.

A dented, rusted or damaged propane cylinder may be 
hazardous and should be checked by your cylinder sup

-

plier. Never use a propane cylinder with a damaged valve 
connection.
The propane cylinder must be constructed and marked in 
accordance with the specifications for LP gas cy

l

inders of 

the U.S. Department of Transportation(DOT) or the 
Standard for Cylinder

,

 Spheres & Tubes for 

transportation 

of Dangerous Goods & Commission, CAN/CSA-B339, as 
applicable.
Never connect an unregulated propane cylinder to the 
heater.

The cylinder must include a collar to protect the
cy

l

inder valve. 

Provided with a listed overfilling prevention device.
Provided with a cylinder connection device compatible with 
the connection for the appliance.
Do not store a 

sp

are LP-Gas cylinder under or near this 

appliance.

A cylinder must be stored outdoors in a well-ventilated 
area out of reach of children. A disconnected cylinder 
must have dust caps tightly installed and must not be 
stored in a building, garage or any other enclosed area.

Never fill the cylinder beyond 80 percent full.

Place the dust cap on the cylinder valve outlet whenever 
the cylinder is not in use.

 

Only install the type of dust cap 

on the cylinder valve that is provided with the cylinder 
valve.

 Other types of caps or plugs may result in leakage 

of propane.


9

Figure 1

Содержание HYPH4601-4

Страница 1: ...HYPH4601 4 READ BEFORE USE Model No Item No 67775...

Страница 2: ...ervice this heater This product is fueled by propane gas Propane gas is invisible odorless and flammable An odorrant is nor mally added to help detect leaks and can be described as a rotten egg smell...

Страница 3: ...watery eyes headaches dizziness fatigue and possibly death You can t see it and you can t smell it It s an in visible killer If these symptoms are present during operation of this product get fresh ai...

Страница 4: ...24 in 60 9 cm and sides 24 in 60 9 cm 24 in 60 9cm 24 in 60 9cm 4...

Страница 5: ...be Ring D 1 Mesh Guard E 3 Upper Supporter F 3 Upper Combination G 1 Tank Housing Supporter H 1 Wheel I 1 Handle M5x12 screw J 1 K 6 Attached into the upper supporter Attached into the burner cover in...

Страница 6: ...o wheel assembled into handle assembled into handle in hardware packing in hardware packing in hardware packing in hardware packing M8x16 screw in hardware packing O 3 M8 lock nut P 2 M6 nuts Q 1 M6 w...

Страница 7: ...ng supporter H into the base hole and the tank housing and don t fasten them Step 4 Attach the burner B into the tank housing top and make the control knob faced to the door and hole to hole use 4pcs...

Страница 8: ...he glass tube ring 4 4 4 5 5 1 5 2 Step 9 Put the upper combination G into the supporter and glass tube to make sure the three holes match up and use screws from Step 7 to fasten them Step 10 Assemble...

Страница 9: ...linder must be constructed and marked in accordance with the specifications for LP gas cylinders of the U S Department of Transportation DOT or the Standard for Cylinder Spheres Tubes for transportati...

Страница 10: ......

Страница 11: ......

Страница 12: ...ing garage or any other enclosed area This appliance may be installed with shelter no more inclusive than 1 With walls on all sides but with no overhead cover 2 Within a partial enclosure which includ...

Страница 13: ...L BOND TOLL FREE 1 866 771 BOND 2663 OR TO BETTER EXPEDITE YOUR REQUEST FEEL FREE TO EMAIL US customer service bondmfg com OR VISIT OUR WEBSITE UNDER CUSTOMER SERVICE SUPPORT www bondmfg com BOND MANU...

Отзывы: