![BOND MANUFACTURING HYFP50095-3 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/bond-manufacturing/hyfp50095-3/hyfp50095-3_owners-manual_2786728008.webp)
LP (Liquid Propane) gas supply connection
•
•
To Connect:
1
2
To Disconnect:
1
2
IMPORTANT
1
2
3
4
5
6
7
8
9
Do not obstruct the flow of combustion air and ventilation air to the appliance.
Disconnect the propane cylinder from the regulator valve when the appliance is not in use.
VISUAL CHECK
Ensure that there is no debris caught in the head of gas cylinder, head of the regulator valve.
Minimum Clearance from Unit to Combustible Materials
72”(182.9cm) from the top; 48” (121.9 cm) from all sides and back.
Do not locate this appliance under any overhead enclosure.
Position the appliance so that you have easy access to the control
knob.
Insert the nipple of the valve coupling into the cylinder valve and tighten the black coupling nut
by turning it clockwise with one hand while holding the regulator with the other hand. (See
diagram.)
Hand tighten only.
SELECTING A LOCATION
Make sure any open flames or cigarettes are extinguished.
Ensure the burner control knob is in the "OFF" position
Remove the battery.
LEAK TEST
Perform a leak test in a well ventilated area outside
Always confirm that the burner control knob is in the OFF position before connecting the gas supply.
In a bowl, create a soap solution using 1 part water and 1 part liquid detergent
Always place this outdoor appliance on a hard, level non-combustible
surface such a concrete, rock or stone.
A gas leak will be detected by expanding bubbles originating from the point of the leak
If a leak is found at any connection point or if you smell gas, close the tank valve, disconnect the tank and do not use the
appliance until repairs can be made.
Hold the regulator with the one hand and loosen the black
coupling nut by turning it counter-clockwise with the other
hand. (See diagram.)
Open LP tank valve.
Always confirm that the cylinder valve is in the OFF position
before disconnecting the gas supply.
Prior to each use, check the hose and valve for excessive wear or abrasions.
Apply the soapy water solution to all connections.
8