Check that battery is correctly inserted.
Insert an opened paperclip into each of the burner ports to clean
them. Ensure the appliance is off and all parts are cooled before
attempting to clean the burner ports
Clean the venturi
Check hose for bends or kinks
Check LP tank connection.
Check if gas cylinder is empty. If yes, replace.
CORRECTIVE ACTION
Wipe dry with a cloth
Burner ports are clogged
Irregular flame pattern or flame does not
come out of the entire length of the burner
Make sure all the gas burner ports are free of any lava rocks or
debris to allow the gas to flow freely.
See "Burner will not light using a match" above.
See "Sudden drop in gas flow" above
Check if gas cylinder is empty. If yes, replace.
Increase flame to "High"
No gas flow
Excess flow safety valve
has been activated
Sudden drop in gas flow
High or gusting winds
Flame blow out
Turn the control knob to "OFF", Close the LP tank valve and
disconnect the regulator from the tank. Turn the control knob to
"HIGH". Wait 1 minute. Turner the control knob to "OFF".
Reconnect regulator to LP tank. Open tank valve slowly. Light
appliance as indicated in "To Light" section.
Check if gas cylinder is empty. If yes, replace.
Check the regulator hose for bends or kinks
Appliance emits a lot of black smoke
when lit
Excess flow safety valve
has been activated
Gas flow is obstructed
Spider webs or insect nest
in the venturi (end of
burner tube)
Burner ports are clogged
Regulator hose is pinched
Burner will not light using a match
Appliance won't light
TROUBLESHOOTING
PROBLEM
Call customer service for replacement part
Reconnect wire to the igniter box
located inside the table base behind
the igniter button
Call customer service for replacement part
CAUSE
www.bondmfg.com
1-866-771-BOND(2663) OR TO BETTER
EXPEDITE YOUR REQUEST FEEL FREE TO EMAIL US
OR LOG IN TO OUR WEBSITE UNDER CUSTOMER SERVICE SUPPORT
Igniter battery is
incorrectly inserted.
Regulator is not fully
connected to the tank
Electrode wire is shorting
between valve and igniter
pin
PLEASE CALL BOND TOLL FREE #
No gas flow
Igniter pin and burner are
wet
Electrode wire is loose or
disconnected
No gas flow
Igniter pin cracked or
broken
IF YOU HAVE QUESTIONS OR CONCERNS
Flame is obstructed at
burner ports