background image

(c)

Use the table that follows to make sure that the crew oxygen system is fully
pressurized:

CREW OXYGEN SYSTEM

AMBIENT TEMPERATURE

FULLY PRESSURIZED

100°F (37°C)

1990 psi (13.720 kPa)

80°F (27°C)

1990 psi (13.100 kPa)

60°F (16°C)

1805 psi (12.445kPa)

40°F (4°C)

1710 psi (11.790 kPa)

20°F (−7°C)

1620 psi (11.170 kPa)

0°F (−18°C)

1530 psi (10.549 kPa)

−20°F (−29°C)

1435 psi (9894 kPa)

−40°F (−40°C)

1340 psi (9239 kPa)

(d)

If the crew oxygen system is not fully pressurized, do the servicing of the crew
oxygen system (TASK 12−14−35−614−801).

(4)

Remove the external ac power (TASK 12−00−07−861−802).

D.

Close Out

(1)

Remove all tools, equipment, and unwanted materials from the work area.

(2)

Close the oxygen service door that follows:

ACCESS                                                     DESIGNATION

212BR

Door Oxygen Refill Connection

CL−604 AIRCRAFT MAINTENANCE MANUAL − PART II

EFFECTIVITY:   ALL

12−14−35

Page 302

Nov 28/2008

Содержание CHALLENGER 604

Страница 1: ...ine the pressure gauge 1 Make note of the value shown on the pressure gauge 1 2 Examine the overboard discharge indicator 2 Make sure that the green disc on the indicator 2 is not broken If the green...

Страница 2: ...si 10 549 kPa 20 F 29 C 1435 psi 9894 kPa 40 F 40 C 1340 psi 9239 kPa d If the crew oxygen system is not fully pressurized do the servicing of the crew oxygen system TASK 12 14 35 614 801 4 Remove the...

Страница 3: ...ircraft with two oxygen cylinders have two overboard discharge indicators NOTE CL 604 AIRCRAFT MAINTENANCE MANUAL PART II Quantity Check of the Crew Oxygen System Servicing Figure 301 EFFECTIVITY ALL...

Страница 4: ...u use the correct equipment configuration C Consumable Materials REFERENCE DESIGNATION MANUFACTURERS REFERENCE AND OR SPECIFICATION 05 038 Oxygen Aviator s Breathing Gas MIL O 27210 Type 1 D Job Set U...

Страница 5: ...OIL OR SOLVENTS THEY CAN START TO BURN 1 Do the servicing of the oxygen system as follows a Use an oxygen mask and set the regulator valve to N b Remove the dust cap 3 from the oxygen filler valve 4 c...

Страница 6: ...at the oxygen filler valve 4 to release the pressure out of the filler line h When the pressure is released from the filler line disconnect the filler line from the oxygen filler valve 4 i Install th...

Страница 7: ...2 1 Aircraft with two oxygen cylinders have two overboard discharge indicators NOTE CL 604 AIRCRAFT MAINTENANCE MANUAL PART II Servicing of the Oxygen System Servicing Figure 302 EFFECTIVITY ALL 12 14...

Страница 8: ......

Отзывы: