background image

TASK 12−14−35−614−801

2.

Servicing of the Oxygen System

A.

Reference Information

REFERENCE                                                      DESIGNATION

TASK 12−00−07−861−802

Remove External AC Power

TASK 12−14−35−610−801

Quantity Check of the Oxygen System

TASK 35−00−00−910−801

Oxygen Safety Precautions

TASK 35−11−01−000−801

Removal of Oxygen Cylinder and Regulator
Assembly

TASK 35−11−01−400−801

Installation of Oxygen Cylinder and Regulator
Assembly

B.

Tools and Equipment

REFERENCE                                                      DESIGNATION

GSE 24−00−24

Tag, Circuit Breaker

NOTE:

Refer to the Illustrated Tool and Equipment Manual to make sure that you use
the correct equipment configuration.

C.

Consumable Materials

REFERENCE                       DESIGNATION                         MANUFACTURERS’ REFERENCE

AND/OR SPECIFICATION

05−038

Oxygen, Aviator’s Breathing, Gas

MIL−O−27210 Type 1

D.

Job Set−Up

WARNING:

BEFORE YOU DO MAINTENANCE ON THE OXYGEN SYSTEM, MAKE
SURE THAT THE EXTERNAL ELECTRICAL POWER IS NOT
CONNECTED. MAKE SURE THAT ALL PRIMARY CIRCUIT BREAKERS
FOR THE AIRCRAFT BATTERIES ARE OPEN AND SAFETIED. IF YOU
ENERGIZE THE ELECTRICAL POWER SOURCE, OR A SPARK
OCCURS NEAR AN OXYGEN LEAK, A FIRE/EXPLOSION CAN
OCCUR. THIS CAN CAUSE INJURY TO PERSONS, AND DAMAGE TO
EQUIPMENT.

(1)

Make sure that the external ac electrical power is not connected
(TASK 12−00−07−861−802).

CL−604 AIRCRAFT MAINTENANCE MANUAL − PART II

EFFECTIVITY:   ALL

12−14−35

Page 304

May 29/2009

Содержание CHALLENGER 604

Страница 1: ...ine the pressure gauge 1 Make note of the value shown on the pressure gauge 1 2 Examine the overboard discharge indicator 2 Make sure that the green disc on the indicator 2 is not broken If the green...

Страница 2: ...si 10 549 kPa 20 F 29 C 1435 psi 9894 kPa 40 F 40 C 1340 psi 9239 kPa d If the crew oxygen system is not fully pressurized do the servicing of the crew oxygen system TASK 12 14 35 614 801 4 Remove the...

Страница 3: ...ircraft with two oxygen cylinders have two overboard discharge indicators NOTE CL 604 AIRCRAFT MAINTENANCE MANUAL PART II Quantity Check of the Crew Oxygen System Servicing Figure 301 EFFECTIVITY ALL...

Страница 4: ...u use the correct equipment configuration C Consumable Materials REFERENCE DESIGNATION MANUFACTURERS REFERENCE AND OR SPECIFICATION 05 038 Oxygen Aviator s Breathing Gas MIL O 27210 Type 1 D Job Set U...

Страница 5: ...OIL OR SOLVENTS THEY CAN START TO BURN 1 Do the servicing of the oxygen system as follows a Use an oxygen mask and set the regulator valve to N b Remove the dust cap 3 from the oxygen filler valve 4 c...

Страница 6: ...at the oxygen filler valve 4 to release the pressure out of the filler line h When the pressure is released from the filler line disconnect the filler line from the oxygen filler valve 4 i Install th...

Страница 7: ...2 1 Aircraft with two oxygen cylinders have two overboard discharge indicators NOTE CL 604 AIRCRAFT MAINTENANCE MANUAL PART II Servicing of the Oxygen System Servicing Figure 302 EFFECTIVITY ALL 12 14...

Страница 8: ......

Отзывы: