www.bomaxengineering.com
/
/ BM Owner’s Manual Ver.01-2008 Page 17
position. For Electric Cut-Out Lever (optional), make sure the lever is held down to be in
the ON position. Throttle Lever is set to low position.
CAUTION:
NEVER
disable or disconnect the Centrifugal Cut-Out Switch or
Electric Cut-Out Lever
(optional)
. It is provided for the operators’
safety and injury may result if it is disabled, disconnected or
improperly maintained.
CAUTION:
The Trowel is
heavy
and
awkward
to move around. Use
appropriate lifting device and proper heavy lifting procedures.
DO
NOT lift the Trowel by the guard rings.
START PROCEDURE
CAUTION:
DO NOT
attempt to operate the Trowel until the Safety Information
and Inspection sections of this manual have been
READ
and
thoroughly
UNDERSTOOD
. Depending on engine manufacturer,
operating steps may vary. See engine manufacturers operating
manual.
SHOWN BELOW HONDA ENGINE
1.
Place the engine
Fuel Valve Lever
(Figure 1) to the
“ON”
position.
Figure 1. Engine Fuel Valve Lever
2.
Place the
Choke Lever
(Figure 2) to the
“OPEN”
position.