www.bomaxengineering.com
/
/ BM Owner’s Manual Ver.01-2008 Page 15
PRE-OPERATION INSPECTION
CAUTION:
NEVER
operate the Trowel in a confined area
or enclosed structure that does not provide
ample
free flow of air
.
ALWAYS
wear approved eye and hearing protection before
operating the Trowel.
NEVER
place hands or feet inside the guard rings while the engine
is running.
ALWAYS
shut the engine down before performing any
kind of maintenance service on the Trowel.
NOTE
The following Pre-Operation Inspection must be performed before the start of each
work session or after every four hours of use, whichever is first. Please refer to the
maintenance section for detailed guidance. If any fault is discovered, the Trowel must
not be used until the fault is rectified.
1.
Thoroughly inspect the machine for signs of damage. Make sure all guards are in
place and secured.
2.
Check hoses, filler openings, drain plugs and any other areas for signs of leakage.
Fix any leaks before operating.
3.
Check the engine oil level and top up as necessary. Use proper engine oil with the
proper viscosity. (Refer to engine manufacturer manual for specific servicing
instructions)
Table 1. Engine Oil Type
Season
Temperature
Oil Type
Summer
25°C or Higher
SAE 10W-30
Spring / Fall
10°C ~ 25°C
SAE 10W-30/20
Winter
0°C or Lower
SAE 10W-10
4.
Check the engine fuel level and top up as necessary. Use clean fuel. Use of
contaminated fuel may damage the fuel system.