![Bomag BW 213 D-4 Скачать руководство пользователя страница 67](http://html1.mh-extra.com/html/bomag/bw-213-d-4/bw-213-d-4_operating-instructions-maintenance-instructions_2785497067.webp)
Every 500 operating hours
BOMAG
67
BW 213 D-4
5.20 Service the battery
!
Danger
Danger of cauterisation ! Danger of explosion!
When working on the battery do not use open
fire, do not smoke!
The battery contains acid. Do not let acid come
in contact with skin or clothes!
Wear protective clothing!
Do not lay any tools on the battery!
Environment
Dispose of the old battery environmentally.
i
Note
Maintenance free batteries also need care. Main-
tenance free only means that the fluid level does
not need to be checked. Each battery suffers un-
der self-discharge, which may, in not checked oc-
casionally, even cause damage to the battery as a
result of exhaustive discharge.
The following therefore applies for the service
life:
l
Switch off all consumers (e.g. ignition, light, in-
side light, radio).
l
Check open-circuit voltage of the battery at
regular intervals. At least once per month.
Reference values: 12.6 V = fully charged; 12.3 V =
50% discharged.
l
Recharge the battery immediately after an
open-circuit voltage of 12.25 V or less is
reached. Do not perform boost charging.
The open-circuit voltage of the battery occurs ap-
prox. 10 hours after the last charging process or
one hour after the last discharge.
l
After each charging process allow the battery
to rest for one hour before taking it into service.
l
For resting periods of more than one month
you should always disconnect the battery. Do
not forget to perform regular open-circuit volt-
age measurements.
!
Caution
Exhausted batteries (batteries with formation
of sulphate on thge plates are not covered un-
der warranty!
l
Open the engine hood and remove the cover-
ing.
Fig. 88
l
Remove the battery (Fig. 88) and clean the
battery compartment.
l
Clean the outside of the battery.
l
Clean battery poles and pole clamps and
grease them with pole grease (Vaseline).
l
Check the fastening of the battery.
l
On serviceable batteries check the acid level,
if necessary top up to the filling mark with dis-
tilled water.
Charging voltage recommendation
Fig. 89
Содержание BW 213 D-4
Страница 2: ......
Страница 7: ...BOMAG 7 BW 213 D 4 1 Technical Data...
Страница 11: ...BOMAG 11 BW 213 D 4 2 Safety regulations...
Страница 18: ...Safety regulations BOMAG 18 BW 213 D 4...
Страница 19: ...BOMAG 19 BW 213 D 4 3 Indicators and Controls...
Страница 20: ...Indicators and Controls BOMAG 20 BW 213 D 4 Fig 5...
Страница 30: ...Indicators and Controls BOMAG 30 BW 213 D 4 Constant end of compaction...
Страница 31: ...BOMAG 31 BW 213 D 4 4 Operation...
Страница 46: ...Operation BOMAG 46 BW 213 D 4...
Страница 47: ...BOMAG 47 BW 213 D 4 5 Maintenance...
Страница 95: ...BOMAG 95 BW 213 D 4 6 Trouble shooting...
Страница 99: ...Trouble shooting BOMAG 99 BW 213 D 4...
Страница 100: ...Trouble shooting BOMAG 100 BW 213 D 4...
Страница 101: ......
Страница 102: ......