As required
BOMAG
52
BVP 10/36, BVP 18/45
5.22 Flushing the water sprinkler
system
*
Fig. 60
l
Remove the cover (2) (Fig. 60) from the water
tank and the lateral rubber cap (3) from the
sprinkler tube.
l
Open the shut-off cock (1).
l
Flush the water tank with a strong water jet,
until all dirt has run out.
l
Press the rubber cap back on.
!
Caution
In case of frost drain the water tank complete-
ly.
5.23 Tightening the screws
i
Note
Self locking nuts must always be replaced by new
ones after they have been unscrewed.
Fig. 61
*Strength classes for screws with untreated, non-
lubricated surfaces. The quality designations are
stamped on the screw heads.
8.8 = 8 G
10.9 = 10 K
12.9 = 12 K
The values result in a 90% utilization of the screw's
yielding point at a coefficient of friction of
μ
total =
0.14.
The compliance with the tightening torques is to be
checked with torque wrenches.
The tightening torques are not applicable when us-
ing MoS
2
lubricants.
*
Optional equipment
Go to
Discount-Equipment.com
to
order your parts