Operation
BOMAG
26
BPR 45/55 D, BPR 55/65 D
Fig. 17
l
Shift the travel lever (Fig. 17) to position "0".
Caution
!
Run the starting process for maximum 20 sec-
onds without interruption and pause for a
minute between starting attempts.
If the engine has not started after two attempts,
determine the cause.
Note
i
The starter switch is designed with a re-start lock.
For a new starting attempt turn the ignition key first
back to position "0".
Fig. 18
l
Turn the ignition key to position "I" (Fig. 18),
the warning buzzer sounds.
l
Then turn the ignition key further to position "II"
to start the engine.
l
As soon as the engine runs, return the ignition
key to position "I". The warning buzzer stops.
Fig. 19
l
After starting take the throttle lever back to po-
sition "MIN" (Fig. 19).
l
Run the engine warm for approx. 1 to 2 min-
utes in idle speed.
Note
i
Operation of the vibratory plate can be started as
soon as the engine responds to short throttle com-
mands.
Caution
!
When the engine is running leave the ignition
key in position "I".
690184
0
Содержание BPR 45/55 D
Страница 2: ......
Страница 7: ...BOMAG 7 BPR 45 55 D BPR 55 65 D 2 Technical Data...
Страница 13: ...BOMAG 13 BPR 45 55 D BPR 55 65 D 3 Safety regulations...
Страница 19: ...BOMAG 19 BPR 45 55 D BPR 55 65 D 4 Indicators and Controls...
Страница 23: ...BOMAG 23 BPR 45 55 D BPR 55 65 D 5 Operation...
Страница 34: ...Operation BOMAG 34 BPR 45 55 D BPR 55 65 D...
Страница 35: ...BOMAG 35 BPR 45 55 D BPR 55 65 D 6 Maintenance...
Страница 42: ...Maintenance BOMAG 42 BPR 45 55 D BPR 55 65 D...
Страница 52: ...Maintenance every 6 months BOMAG 52 BPR 45 55 D BPR 55 65 D...
Страница 61: ...BOMAG 61 BPR 45 55 D BPR 55 65 D 7 Trouble shooting...
Страница 67: ...BOMAG 67 BPR 45 55 D BPR 55 65 D 8 Disposal...
Страница 69: ......
Страница 70: ......