EFIR-K 

ROLLING CODE UHF 

REMOTE CONTROL SET

 

(version 2.2) 

USER’S MANUAL

 

 

 

DESCRIPTION 

Efir-

К

 Rolling Code UHF Remote Control Set is the strong encryption personal simplex radio system 

intended to transmit control signals. 

This device is designed as an alarm and remote control system. Efir-K enables to activate features such 

as arming, disarming, utility and panic on your security system from the palm of your hand. 

The Efir-

К

 Remote Control Set consists of: 

 

2-Button Keyfob, which is a RF transmitter with rolling (or dynamic, or hopping) code capability to 
provide security, and

 

 

Receiver,

 which is 

a wireless relay switch controlled by

 a Keyfob. 

One transmitter is included into an Efir-K delivery set. A relay switch can be controlled with up to 

fourteen additional transmitters. 

Efir-

К

 is useful to: 

 

Work as part of an integrated security systems (for arming/disarming, opening/closing of doors, 
garage door openers or any movable barriers, or for notification appliances) 

 

Remote relay control of diverse devices 

 

Ensure human safety by means of panic signal transmitting to the Alarm Receiving Center in case of 
intruder attack 

 

Provide a selected remote access 

FEATURES

 

Strong encrypted RF transmission

 

 

Remote control by up to 15 Keyfobs 

 

Lost Keyfob disabling 

 

LED indicating of relay actuation and learning mode entering 

 

Choosing of suitable operating mode from four available 

 

Built-in tamper switch enabling to detect unauthorized lid removing in order to avoid unauthorized 

Keyfob operations 

 

Relay output with switch-over contacts (up to 3 A) enabling to manipulate remotely by such low 

voltage devices as visual/audible alarms, video cameras, locks, garage door openers, and motors 

SPECIFICATIONS 

RF Carrier Frequency 

433,92 MHz 

Signal Encoding Technique 

dynamic code 

Receiver Working Range 

up to 60 m 

Number of Operating Modes 

Keyfob RF Power Output 

5,0 mW maximum 

Maximum Number of Keyfobs 

15 

Receiver Power Requirements 

10 

÷

 14,5 Vdc 

Consuming Current (in case of 12 V voltage): 

o

 

for Non-Operating Relay  6 mA 

o

 

for Operating Relay 

15 mA 

ISO 9001

Содержание EFIR-K

Страница 1: ...le barriers or for notification appliances Remote relay control of diverse devices Ensure human safety by means of panic signal transmitting to the Alarm Receiving Center in case of intruder attack Provide a selected remote access FEATURES Strong encrypted RF transmission Remote control by up to 15 Keyfobs Lost Keyfob disabling LED indicating of relay actuation and learning mode entering Choosing ...

Страница 2: ...ver transmitter position Large building constructions and metal objects power lines vehicles as well as humans can disturb RF propagation Landscape details and surrounding vegetation can also attenuate the signal In order to improve range of performance attach the Receiver upright away from strong thermal sources air conditioners direct sunlight places likely to cause water drops within the Receiv...

Страница 3: ...g with EOL resistor in series The value of EOL resistor is strongly dependent on specified connecting scheme and the equipment the tamper to be connected to so this subject is beyond the scope of this manual 6 Replace the Receiver lid 7 Power up the Receiver and the executive device RECEIVER OPERATING MODES A short pressing on the large Keyfob button activates the relay while a short pressing on t...

Страница 4: ...ution Holding the LEARN button for more than 8 seconds will erase the Receiver memory so that data about all Keyfobs programmed before will be lost 5 Shortly press large or small Keyfob button and ensure the Receiver LED goes off If the LED has no gone off then the RF relationship between Receiver and Keyfob is not created DCaution If the programming Keyfob button is not pressed within 30 second i...

Страница 5: ...tch over relay dry contacts to the Security Station communication line The Receiver wiring diagram for such an application is shown in Figure 3 5 Connect the Receiver to a usable power supply Such a system operates as follows As needing help any security system owner sends out an encoding panic signal by means of corresponding Keyfob button pressing The Receiver detects the signal and decrypts it ...

Страница 6: ...ields 4 Wire the Receiver to your SIGNAL equipment according with the scheme in Figure 4 and directions from Table 1 Such a system operates as follows Being coming out of premises an owner closes the door and presses on the large Keyfob button An encoded control signal is sent out at once The signal is detected and decoded by Receiver In case of authorization having been successful the Receiver re...

Страница 7: ...set to ARMED position that is has to be pushed Solder to the contacts 1 and 2 of S3 switch 1 NO opened ХТ2 3 12V 12 2 СОМ common ХТ2 12V 11 2 12V ХТ1 SIGNAL VK2 ХТ2 3 ХТ2 12V 12 4 12V ХТ2 Armed disarmed 11 2 СОМ common ХТ3 Armed disarmed 12 3 NС closed ХТ2 12V 11 2 12V XT1 SIGNAL VK 4P ХТ2 12V 12 4 12V ХТ2 Crypto Device 1 NO opened ХТ5 Crypto Device 2 СОМ common ХТ2 12V 9 2 12V XT1 SIGNAL VK4 iss ...

Страница 8: ...n encrypted executive signal The Receiver detects the signal and decodes it If the signal is authorized the switch over dry contacts are opened following by the lock opening In such a process the Receiver LED shall light by red After having gone from the object the owner closes the door and releases the large Key button The Receiver LED shall go out The lock switches on blocking the door Coming ba...

Страница 9: ...ls and workmanship for 12 months since putting the Efir K into operation but no more then 18 months since production under normal use and service Sending off the Efir K to the manufacturer for repairing accompany those with a damage certificate describing the defect Send your complaints to the manufacturer at the following address ZAO NVP BOLID 4 Pionerskaya street Korolyov Moscow Region Russia 14...

Страница 10: ... Set Product Designation Serial Number Produced tested by quality control department in compliance with state standards and specifications packed by NVP BOLID Company and qualified as deliverable Q C STAMP _____________________ ____________________________ Name Date ...

Отзывы: