background image

 

RECEIVER OPERATING MODE PROGRAMMING 

1. 

Power off the Receiver and remove the Receiver lid. 

2.

 

Put on the jumper J. 

3.

 

Connect a 12 Vdc power supply to the Receiver. 

4.

 

Power on the Receiver. 

5.

 

Consider the Receiver periodically blinking. The number of flashes in sets (singly, by twos, in trees 
or in fours) denotes the current operating mode number. 

6.

 

To increase the operating mode number press the large Keyfob button. Inversely, to decrement the 
operating mode number press the small Keyfob button. 

7.

 

Power off the Receiver. 

8.

 

Take off the jumper J in order to save the changes. 

ADDITIONAL KEYFOB PROGRAMMING 

1. 

Take off the Receiver lid. 

2.

 

Connect the Receiver to a 12 ± 2 V direct power supply. Power on the Receiver. 

3.

 

Ensure there are no other operating RF transmitters closer than 50 meters. 

4.

 

Shortly (within no more than 2 seconds) press the LEARN button located on the Receiver PC board 
to program a new Keyfob. The Receiver LED shall light up indicating programming mode initiating. 

D

Caution

: Holding the LEARN button for more than 8 seconds will erase the Receiver memory so 

that data about all Keyfobs programmed before will be lost. 
5.

 

Shortly press large or small Keyfob button and ensure the Receiver LED goes off. If the LED has no 
gone off then the RF relationship between Receiver and Keyfob is not created. 

D

Caution

: If the programming Keyfob button is not pressed within 30 second interval, having been 

expired since Receiver programming mode initiating (pressing of the PC board LEARN button), the 
programming mode will be prohibited. To resume the programming procedure return to the step 4. 
6.

 

In case of programming having been successful (the Receiver LED has gone off after pressing a 
Keyfob button) press the Keyfob button once more. 

7.

 

To program another Keyfob (no more than 14 additional ones can be programmed) repeat the steps 
from 4 to 6. 

8.

 

Bring the lid back onto the Receiver base. 

9.

 

Ensure all programmed Keyfobs are capable to operate properly having been located at the ordinary 
places. 

RECEIVER MEMORY CLEARING 

Remove the Receiver lid and keep LEARN button pushed for more than 8 seconds. All Keyfobs data 

having been already registered will be deleted. 

Содержание EFIR-K

Страница 1: ...le barriers or for notification appliances Remote relay control of diverse devices Ensure human safety by means of panic signal transmitting to the Alarm Receiving Center in case of intruder attack Provide a selected remote access FEATURES Strong encrypted RF transmission Remote control by up to 15 Keyfobs Lost Keyfob disabling LED indicating of relay actuation and learning mode entering Choosing ...

Страница 2: ...ver transmitter position Large building constructions and metal objects power lines vehicles as well as humans can disturb RF propagation Landscape details and surrounding vegetation can also attenuate the signal In order to improve range of performance attach the Receiver upright away from strong thermal sources air conditioners direct sunlight places likely to cause water drops within the Receiv...

Страница 3: ...g with EOL resistor in series The value of EOL resistor is strongly dependent on specified connecting scheme and the equipment the tamper to be connected to so this subject is beyond the scope of this manual 6 Replace the Receiver lid 7 Power up the Receiver and the executive device RECEIVER OPERATING MODES A short pressing on the large Keyfob button activates the relay while a short pressing on t...

Страница 4: ...ution Holding the LEARN button for more than 8 seconds will erase the Receiver memory so that data about all Keyfobs programmed before will be lost 5 Shortly press large or small Keyfob button and ensure the Receiver LED goes off If the LED has no gone off then the RF relationship between Receiver and Keyfob is not created DCaution If the programming Keyfob button is not pressed within 30 second i...

Страница 5: ...tch over relay dry contacts to the Security Station communication line The Receiver wiring diagram for such an application is shown in Figure 3 5 Connect the Receiver to a usable power supply Such a system operates as follows As needing help any security system owner sends out an encoding panic signal by means of corresponding Keyfob button pressing The Receiver detects the signal and decrypts it ...

Страница 6: ...ields 4 Wire the Receiver to your SIGNAL equipment according with the scheme in Figure 4 and directions from Table 1 Such a system operates as follows Being coming out of premises an owner closes the door and presses on the large Keyfob button An encoded control signal is sent out at once The signal is detected and decoded by Receiver In case of authorization having been successful the Receiver re...

Страница 7: ...set to ARMED position that is has to be pushed Solder to the contacts 1 and 2 of S3 switch 1 NO opened ХТ2 3 12V 12 2 СОМ common ХТ2 12V 11 2 12V ХТ1 SIGNAL VK2 ХТ2 3 ХТ2 12V 12 4 12V ХТ2 Armed disarmed 11 2 СОМ common ХТ3 Armed disarmed 12 3 NС closed ХТ2 12V 11 2 12V XT1 SIGNAL VK 4P ХТ2 12V 12 4 12V ХТ2 Crypto Device 1 NO opened ХТ5 Crypto Device 2 СОМ common ХТ2 12V 9 2 12V XT1 SIGNAL VK4 iss ...

Страница 8: ...n encrypted executive signal The Receiver detects the signal and decodes it If the signal is authorized the switch over dry contacts are opened following by the lock opening In such a process the Receiver LED shall light by red After having gone from the object the owner closes the door and releases the large Key button The Receiver LED shall go out The lock switches on blocking the door Coming ba...

Страница 9: ...ls and workmanship for 12 months since putting the Efir K into operation but no more then 18 months since production under normal use and service Sending off the Efir K to the manufacturer for repairing accompany those with a damage certificate describing the defect Send your complaints to the manufacturer at the following address ZAO NVP BOLID 4 Pionerskaya street Korolyov Moscow Region Russia 14...

Страница 10: ... Set Product Designation Serial Number Produced tested by quality control department in compliance with state standards and specifications packed by NVP BOLID Company and qualified as deliverable Q C STAMP _____________________ ____________________________ Name Date ...

Отзывы: