3.3  bp408 testing program 

The tests for the following variants are described herein: 
a)  the gearless drive unit with UCM braking system on the 

traction sheave 

b)  the drive unit with gear (without UCM braking system on 

the  traction  sheave)  and  with  UCM  speed  limiter  and 
UCM safety gear 

c)  the hydraulic elevator (UCM valve) 
d)  The testing sequence must be observed. 

3.3.1  General testing sequence 

During the test the overspeed monitoring of the lift controller is 
disabled. 
 

3.3.1.1 

Step 1 

In order to check this function prior to commissioning, the 
bp408 system module contains a test program The test pro-
gram is activated by a password in the maintenance menu.

 

 
The  password  can  be  assigned  by  the  user  in  the  setup 
menu and may amount to a maximum of 8 digits. The de-
fault code upon delivery is “8103”.

 

 

 

  After entering of the test code, a warning note is pro-

vided on the display of the control system. 

 

The  hazard  warning  "Caution! 
Refer  to  the  testing  instruc-
tions!" appears in the display of 
the  control  system  after  acti-
vating 

the 

testing 

mode. 

 

Содержание Schmersal bp408

Страница 1: ...Operating Instructions The bp408 Safety Circuit General Information EC Type Examination Safety Circuit www boehnkepartner de...

Страница 2: ...anual does not provide exhaustive information on our entire set of delivery options Irrespective of the attention paid during creation of texts images and programs we cannot assume legal liability for...

Страница 3: ...ation 11 3 2 3 Notes on function 12 3 2 4 Notes on test 12 3 3 bp408 testing program 14 3 3 1 General testing sequence 14 3 3 1 1 Step 1 14 3 3 1 2 Step 2 16 3 3 1 3 Step 3 16 3 3 2 Extra requirements...

Страница 4: ...4 5 Connection of SPL 01 23 4 6 Safety circuit status bar on display 23 5 Technical data 24...

Страница 5: ...prove clarity and structur ing the manual was divided into multiple parts The In struction Manual of the bp408 Safety Circuit also considers the dangers and risks which may lead to severe health re la...

Страница 6: ...s only permitted given the consent of B hnke Partner GmbH and under the inclusion of a pre cise indication of source B hnke Partner GmbH its logo and the company desig nated are protected trademarks T...

Страница 7: ...ntains a safety circuit The safety circuit can be used in the following cases in accordance with EN 81 20 50 Preparatory measures with opened elevator cabin door and elevator shaft door Approach with...

Страница 8: ...8 Figure 2 bp408 system module Section of SPC 01 circuit board Reg No 01 208 5A 6135 00 18...

Страница 9: ...9 2 2 Declaration of conformity Figure 3 Declaration of conformity...

Страница 10: ...max 1 2 m above the level position There must be a resid ual space of at least 1 0 m between the cabin floor and the upper edge of the shaft access The apron fitted beneath the cabin may only al low...

Страница 11: ...fil at least protection class IP2xD Condensation must be avoided on all components Example Water condensation in damp machine room after the control system is switched off In critical environments ple...

Страница 12: ...circuit SMZ on SPL 01 is used for UCM con trol A magnetic switch is sufficient for channel 1 and a position signal from the lift controller for channel 2 e The reaction times of all components must b...

Страница 13: ...module for support purposes f The specialists check the provided acceptable limit val ues of EN 81 20 50 and or EN 81 1 2 A3 for example distances on the elevator system by measuring g The specialist...

Страница 14: ...peed monitoring of the lift controller is disabled 3 3 1 1 Step 1 In order to check this function prior to commissioning the bp408 system module contains a test program The test pro gram is activated...

Страница 15: ...sing the di rectional key in the downward direction This is described in the following chapter If a testing sequence with closed doors is selected it is checked whether the safety circuit has been int...

Страница 16: ...description pertaining to each inverter is provided on request Here the brake and trip contactors are actuated with the door opened and the safety circuit activated until the safety circuit triggers a...

Страница 17: ...switch is activated The elevator will now move with the maximum rated speed or only by opening the brake A braking system tested in accordance with UCM engages and brings the cabin to a stop The trav...

Страница 18: ...without a brake on the traction sheave certified in accordance with UCM suitable braking or arresting systems are prescribed in order to sat isfy EN 81 20 Usually a suitable speed limiter with magneti...

Страница 19: ...check these for flawless operation the inputs on the control system must be disconnected and or provided with a con tinuous signal 24 V The system module detects an erro neous sequence of signals in n...

Страница 20: ...A 12B 13 14 correspond to DIN EN 60664 and or DIN EN 60950 The safety circuit with query unit on bp408 is secured up to a maximum of 2 A The connection of neutral conductor mains potential NN is made...

Страница 21: ...of the control relay K552 may engage first but only if relays K551 K553 and K554 have disengaged By engaging K552 K553 is al lowed to engage which causes the engagement of K554 in turn If relays K553...

Страница 22: ...open continuously During approach and readjustment with the cabin door opened an error therefore causes no bypassing of the door and door lock switch This means that the unlocking zone can only be ap...

Страница 23: ...tus bar is provided on the right side of the display It is shown in all menus The safety circuit sta tus bar provides the following information Pos Meaning Terminal 1 Passive Safety Circuit 10 2 Emerg...

Страница 24: ...A Fuse safety circuit max 2 A Control power supply 24 VDC 10 15 Reaction time UCM detection max 10 ms Protection degree Modul IP20 Housing IP43 Operating temperature 0 C bis 60 C Storage transport te...

Отзывы: