11
3.2 General information on UCM function
3.2.1 Storage, transport and operating conditions
CAUTION!
Improper storage, transport or operating conditions can result in
destruction of the
system and danger to persons.
Storage and transport conditions
Ambient temperature: -20
°
C to 70
°
C,
relative humidity up to max. 90% (non-condensing)
Operating conditions
Ambient temperature: 0
°
C to 60
°
C,
relative humidity up to max. 90% (non-condensing),
Max. height
- Types 230 VAC and 110 VAC: 2000 m
- Type 48 VAC/VDC: 4000 m
The ambient temperature of the control cabinet must be be-
tween 0°C and 40°C. If the operating temperature is below
5°C, disturbance of visible characters on the LCD is expected.
In case of higher ambient temperatures, the cabinet must be
force-cooled (up to 60
°
C using fans, using cooling units
above that). Existing inlets and outlets for air conditioning
must be kept free.
Aggressive mediums, dust, fog, water or humidity must not
reach the assemblies. The control cabinet should hence fulfil
at least protection class IP2xD.
Condensation must be avoided on all components!
Example: Water condensation in damp machine room after
the control system is switched off
In critical environments, please ensure there is enough sound
insulation to the building.
Out system controls are designed for primary voltage 230 V
AC 50 Hz.
When using residual current-protective circuits in control sys-
tems having frequency converters, it must be ensured that
these RCD circuit breakers must be sensitive to universal
current. Other RCD circuit breakers must not be used in ac-
cordance with DIN VDE 0160, 5.5.3.4.2 because the DC re-
sidual current generated through the input circuit of the fre-
quency converter could increase the minimum triggering level
of RCD circuit breaker culminating in non-triggering. The
maximum permissible release current of these selective RCD
circuit breakers that are sensitive to universal current must
not exceed value I
Δ
N=0.3 A.
3.2.2 Notes on installation
a) The UCM components must be used as intended and in
accordance with requirements. The operating instruc-
tions for the entire system (acquisition by the elevator
installing company) must be available.