CLEANING AND LUBRICATING 
 

Cleaning and Lubricating of the FPU is performed to keep the FPU and its associated equipment in good 
operating condition.  The cleaning and lubrication of the FPU can be conducted along with the 
Preventative Maintenance Checks and Services (PMCS) procedures described in (WP 0013 00).  Specific 
areas described below need to be cleaned after an operational event or periodically if stored/staged 
outside of a fixed facility to keep the container, modules, and accessories performing as designed.  
Cleaning also assists in maintaining the condition of the materiel stored within the system.  Any damage 
discovered when cleaning and/or lubricating that cannot be corrected using the troubleshooting 
procedures described in (WP 0011 00) should be reported to maintenance for corrective action. 
 

Table 1 Cleaning 

 

SURFACE 

OIL/GREASE 

SALT/MUD/DIRT 

DEBRIS 

RUST/CORROSION 

Exterior and Interior 

Walls (All) 

Detergent, Water, 

Rags 

Soapy Water, Brush, 

Rags 

Corrosion Removal 

Compound and Wire Brush, 
Dry Rag, Coat with Lube Oil 

or Spot Paint 

Door Seals 

Damp and Dry Rags 

Damp and Dry Rags 

N/A 

Module Cradles, FPU 

Floor 

Detergent, Water, 

Rags (Remove, 

clean, and replace 

rubber pad into 

footing) 

Soapy Water, Brush, 

Rags (Remove, clean 

and replace rubber pad 

into footing) 

Corrosion Removal 

Compound and Wire Brush, 

Dry Rags, Coat with Lube 

Oil or Spot Paint (Remove, 

clean, and replace rubber 

pad into module cradle 

footing) 

Container Door Hinges 

N/A 

Brush, Rag and 

lubricate as needed to 

ensure door hinges 

travel freely 

Corrosion Removal 

Compound and Wire Brush, 

Dry Rags and Lubricate as 

needed 

Door Retaining Straps 

Detergent, Water, 

Rags 

Detergent, Water, Rags 

N/A 

Pallet Ledge Locking 

Rod 

N/A 

Brush, Rag and 

lubricate as needed to 

prevent rust buildup on 

threads 

Corrosion Removal 

Compound and Wire Brush, 

Dry Rags and Lubricate as 

needed 

Содержание BOH-CARGO-12-3

Страница 1: ...H Environmental LLC Chapter 4 Rev 7 01 FPU SYSTEMS OPERATION MANUAL INCLUDING REPAIR PARTS SPECIAL TOOL LIST MODELS FPU 8 4 BOH CARGO 12 3 FPU 20 3 BOH FPU Field Pack up Units CHAPTER 4 OPERATOR MAINT...

Страница 2: ...BOH PM 07 4 Chapter 4 Rev 7 01 This page was intentionally left blank...

Страница 3: ...interval Perform all checks and services keeping in mind the following guidelines Before you begin using the FPU SYSTEM perform Before Operation PMCS checks and services While the FPU SYSTEM is in use...

Страница 4: ...BOH PM 07 4 Chapter 4 Rev 7 01 This page was intentionally left blank...

Страница 5: ...alt Clean as required Check Horizontal Interconnectors for proper function tightness and debris Clean as required and replace if not functioning properly Damage or malfunction that would cause the FPU...

Страница 6: ...BOH PM 07 4 Chapter 4 Rev 7 01 This page was intentionally left blank...

Страница 7: ...covered when cleaning and or lubricating that cannot be corrected using the troubleshooting procedures described in WP 0011 00 should be reported to maintenance for corrective action Table 1 Cleaning...

Страница 8: ...thly or as required if under adverse conditions Door Lock Shaft Pivot Bearing Molykote Multipurpose Synthetic Grease P N 26040124 As Required All Temperatures Monthly or as required if under adverse c...

Страница 9: ...bricate P N 26040123 As Required All Temperatures Monthly or as Required if Under adverse conditions Vertical Rack Stanchion Recessed Rings FPU 8 4 BOH CARGO 12 3 only General Purpose Lubricating Oil...

Страница 10: ...As Required All Temperatures Monthly or as Required if under Adverse Conditions FPU SYSTEM Module Drawer Slam Locks Molykote Multipurpose Synthetic Grease P N 26040124 As Required All Temperatures Mo...

Страница 11: ...dder with hand rail INSPECT 1 Open and close right door A left door B refer to chapter 2 pages 0006 00 9 and 00 10 to ensure proper operation and alignment 2 Visually inspect door seals for damage 3 I...

Страница 12: ...door B slightly when closed to prevent damage to the door edge seals 4 Notify maintenance of any missing or damaged seals and any problems with operation of latch handle or hinges for service 5 Notify...

Страница 13: ...el Parts References None Chapter 2 WP 0005 00 2 and 00 3 Personnel Required Equipment Condition One FPU SYSTEMS Set up INSPECT 1 Raise and lower each of the steps 2 to ensure they stow and operate pro...

Страница 14: ...BOH PM 07 4 Chapter 4 Rev 7 01 This page was intentionally left blank...

Страница 15: ...WP 0006 00 11 to 00 16 Personnel Required Equipment Condition One FPU SYSTEM Set up INSPECT 1 Inspect the vertical rack frame 1 for cracks excessive dents or bending Report to maintenance for repair...

Страница 16: ...BOH PM 07 4 Chapter 4 Rev 7 01 This page was intentionally left blank...

Страница 17: ...to 00 18 Personnel Required Equipment Condition One FPU SYSTEMS Set up INSPECT 1 Inspect pallet 1 for cracks excessive dents or sagging report damage to maintenance for repair or replacement 2 Inspec...

Страница 18: ...BOH PM 07 4 Chapter 4 Rev 7 01 This page was intentionally left blank...

Страница 19: ...IAL SETUP Materiel Parts References None Chapter 2 WP 0006 00 17 Personnel Required Equipment Condition One FPU SYSTEMS Set up INSPECT 1 Remove pallet from container using a forklift 2 Inspect pallet...

Страница 20: ...BOH PM 07 4 Chapter 4 Rev 7 01 This page was intentionally left blank...

Отзывы: