background image

50 Spring Street, Ramsey, NJ 07446, U.S.A.

Tel. 201-934-8500 • Fax: 201-934-9832

www.bogen.com

Limited Warranty; Exclusion of Certain Damages

Accessories/Components

1

. One of the following two back boxes are required for assembly.

BBF - Flush-Mount Back Box

Mounting kit for installing amplifier flush to a wall

BBS - Surface-Mount Back Box

Mounting kit for installing amplifier to the surface of a wall

2. The WMAD is required for assembly.

WMAD - Front Cover / Door

Prevents tampering with system settings

Simple installation

RVCP - Remote Volume Control Panel

Push-button operation of motorized master volume 
control

Fits in standard single gang electrical box

Decora style cover plate

BBF

BBS

WMAD

The following item is an optional accessory.

Mounting Components

Accessories

RVCP

The 

Bogen Power Vector Amplifiers

are warranted to be free from defects in material and workmanship for three (3) years from the date of sale to

the original purchaser. Any part of the product covered by this warranty that, with normal installation and use, becomes defective (as confirmed by
Bogen upon inspection) during the applicable warranty period, will be repaired or replaced by Bogen, at Bogen’s option, provided the product is
shipped insured and prepaid to: Bogen Factory Service Department, 50 Spring Street, Ramsey, NJ 07446, USA. Repaired or replacement product
will be returned to you freight prepaid. This warranty does not extend to any of our products that have been subjected to abuse, misuse, improper
storage, neglect, accident, improper installation or have been modified or repaired or altered in any manner whatsoever, or where the serial number
or date code has been removed or defaced.

THE FOREGOING LIMITED WARRANTY IS BOGEN’S SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASER’S SOLE AND EXCLU-
SIVE REMEDY. BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM
EXTENT ALLOWABLE BY LAW. 

Bogen's liability arising out of the manufacture, sale or supplying of products or their use or disposition, whether

based upon warranty, contract, tort or otherwise, shall be limited to the price of the product. 

IN NO EVENT SHALL BOGEN BE LIABLE FOR SPE-

CIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS, LOSS OF DATA OR LOSS
OF USE DAMAGES) ARISING OUT OF THE MANUFACTURE, SALE OR SUPPLYING OF PRODUCTS, EVEN IF BOGEN HAS BEEN ADVISED
OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES.

Some States do not allow the exclusion or limitation of incidental or

consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also
have other rights which vary from State to State.

Products that are out of warranty will also be repaired by the Bogen Factory Service Department – same address as above or call 201-934-8500.
The parts and labor involved in these repairs are warranted for 90 days when repaired by the Bogen Factory Service Department. All shipping
charges in addition to parts and labor charges will be at the owner's expense. All returns require a Return Authorization number. For most efficient
warranty or repair service, please include a description of the failure.

12/2008

Содержание WV100

Страница 1: ...Wall Mount Power Vector Amplifiers WV100 WV150 WV250 Models Installation and Use Manual 2002 Bogen Communications Inc All rights reserved Specifications subject to change without notice 54 2086 01E 1204 ...

Страница 2: ...n for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufac turer 12 Unplug this apparatus during lightning storms or when unused for long periods of time 13 Refer all servicing to qualified service person...

Страница 3: ...e Speaker Connections 6 COM and GND Terminals 7 Remote Volume Control 7 Mute Control 7 Bridging Mix Bus 7 System Expansion of Power Vector Amplifiers 8 OPERATION 9 10 Front Panel Controls Indicators 9 Input Volume Controls 9 Signal Clip Indicator 9 Bass and Treble Controls 9 Master Volume Control 9 Average Peak Switch LED Output Meter 9 Power Switch Power Indicator 9 Output Limiter 10 Rear Panel C...

Страница 4: ... Control determines maximum amp output level before limiting takes place Indicator illuminates when limiting takes place 5 Average Peak Switch This switch determines whether the LED Output Meter registers the average or peak level of the amplifier s output 6 LED Output Level Meter An 11 segment LED output level meter monitors the output level of the power amplifier 7 Tape Out RCA unbalanced signal...

Страница 5: ...Vector Connector Board Rear 1 Trans Output Direct Out Selector Allows selection of either TRANS for transformer coupled outputs 70V 25V and 8 ohm or DIR for direct low impedance 4 ohm minimum output 2 Speaker Output Barrier Strip A terminal barrier strip with clamping washers provides connections for speaker loads 3 Mute Control Terminals Provides access to mute buses for external control and syst...

Страница 6: ...talled A white screened area is provided on the front of the amplifier below the connector to identify the connector s purpose and associated input number Remove the filler cap in the upper left hand corner of the front panel and install the combination jack as shown in the figures below Either or both of the connector styles on the jack can be wired to any user supplied module with included cable...

Страница 7: ...lar module bay and is not processed by the output module directly The input is includ ed so that the additional input function of the module bay is not forfeited when an output module is installed Input Modules Functionality The Wall Mount Power Vector series of amplifiers accepts Bogen s new advanced plug in input modules which provide a wide range of input types allowing the amplifier inputs to ...

Страница 8: ...e 4Ω terminal and the GND terminal Make sure the selector switch is in the DIR position Bypassing the output transformer and driving the speaker load directly provides the advantage of better bass response To maximize the power delivered to the speakers their combined load impedance should be 4 ohms Connecting higher load impedances is electrically acceptable but the mismatch in load impedance wil...

Страница 9: ...level of the MasterVolume control The impedance of the shorting connections must be less than 100 ohms in order to operate the control Mute Control Each priority bus High Medium and Low can be externally activated This allows priority buses of two or more Wall Mount Power Vector units to be linked together for system expansion purposes A particular mute priority can be externally forced by shortin...

Страница 10: ...is not rec ommended that more than three amplifiers be bridged together due to bridging loss When connecting mute control functions make certain that the wiring is consistent H to H M to M and so forth See illustration below Note When connecting mute control functions between amplifiers make certain that the wiring is consistent H to H M to M and so forth ...

Страница 11: ...ow 40 Hz This filter shape helps to avoid overdriving the speaker s coupling transformer with low frequency signals that may cause noticeable distortion due to magnetic saturation of the transformer s core Master Volume Control The overall volume level of the amplifier is set by a Master Volume control The Master Volume control is motorized and can be controlled by manually adjusting the knob or b...

Страница 12: ... a desired level below the amplifier s maximum level to provide a means of limiting the system s volume level In this case the amplifier is driven to the desired output level and then the Limiter control is adjusted so that it begins to engage In general input and master controls should be set so that the Limiter engages as little as possible Rear Panel Controls Trans Output Direct Out Selector Sw...

Страница 13: ...Block Diagram 11 ...

Страница 14: ...mpedance Transformer Coupled 70V 25V 8 ohms balanced or unbalanced Direct Coupled 4 ohms unbalanced Thermal Emissions WV100 495 2 BTU hr WV150 696 7 BTU hr WV250 911 9 BTU hr Tape Out Output Level 4 VRMS FRP Output Impedance 50 ohms maximum Protection Thermal short circuit and overload auto reset Line Fusing Resettable circuit breaker Cooling Thermally controlled 3 speed fan Power Consumption WV10...

Страница 15: ...connections Trans Out load on wrong tap Bass control boosted too much POOR LOW FREQ RESPONSE NO BASS Power Indicator LED is red Input Signal Clip LED is green LED Output Meter not in red Lo cut switch is set to ON Speakers wired out of phase Check module bass control setting if available Check bass control setting Note Transformer coupled speakers have less bass response Power Indicator LED is red...

Страница 16: ... or repaired or altered in any manner whatsoever or where the serial number or date code has been removed or defaced THE FOREGOING LIMITED WARRANTY IS BOGEN S SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASER S SOLE AND EXCLU SIVE REMEDY BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND EITHER EXPRESS OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DIS...

Страница 17: ......

Отзывы: