49
Status
The
Status
selection for the power amplifier provides real-time status, such as whether
the amplifier is operating in 2-channel mono or single-channel bridged mode, LEDs for
thermal protection and clipping, a real-time reading of the appliance’s temperature, and
indicators for the amplifier’s standby and mute status. Note that the number of channels
that appear depends on whether the amplifier is operating in 2-channel mono or single-
channel bridged mode.
Table 20. Standby Settings
Enable
Enables or disables the standby feature for the amplifier.
Threshold Amp AB
Sets the threshold level for channels A/B.
If the signal level remains below this level for 200 sec
-
onds or longer, the amplifier is put into low power
Standby mode. Normal operation will resume (within
one second) once a signal is received that exceeds this
level.
The range is -144 to +24 dB.
Status
Indicates if channels A/B are in Standby mode (On) or
not (Off).