background image

 

General Safety Instructions 

 
Always follow these basic safety precautions when using the system: 
 
1. Read carefully and understand all instructions. 
2. Follow all warnings and instructions marked on the product. 
3. DO NOT block or cover ventilation slots and openings. 
4. DO NOT place the product in a closed enclosure or cabinet unless proper 

ventilation is provided. 

5. Never spill liquid on the product or drop objects into the ventilation slots and 

openings. Doing so may result in serious damage to the components. 

6. Repair or service must be performed by a factory authorized repair facility. 
7. A UL/CSA approved power pack is provided. 
8. DO NOT staple or otherwise attach the power supply cord to building surface. 
9. DO NOT use the product near or in wet or damp places, such as wet basements. 
10. DO NOT use extension cords. Install within six feet of a grounded outlet 

receptacle. 

11. DO NOT install during lightning storm. 
12. Never touch un-insulated wires or terminals unless the unit is disconnected from 

both power and the rest of the phone system. 

13. Use Caution when installing or modifying configuration switches or control lines. 
14. The unit must be securely attached to a wall board, rack or table mounted. 
 
 

CAUTION: 

If any wiring from the system leaves the premises, 
you must use proper electrical protectors. 

 
 

Regulations: 

 

FCC (Part 15) Radio Frequency Interference 

 
The BOMDMU generates and uses radio frequency energy and if not installed and 
used in strict accordance with the manufacturer's instructions, may cause interference 
to radio and television reception. Unit complies with the limits for Class A devices in 
accordance with the specifications in Subpart J of Part 15 of the FCC Rules. This 
testing is designed to provide reasonable protection against such interference. 
However, there is no guarantee that interference will not occur in a particular 
installation. If this equipment does cause interference to radio or television reception, 
which can be determined by turning the unit off and on, the user is encouraged to try 
to correct the interference by one or more of the following measures: 
 

 

Reorient the radio or TV receiving antenna. 

 

 

Relocate the unit with respect to the radio or TV receiver or vice-versa. 

 

 

Plug the unit into a different outlet so that it and the radio or TV receiver are 
on different branch circuits 

 

 

If necessary, the user should consult the dealer or an experienced 
radio/television technician for additional suggestions. 

 

 

 

 

Limited Warranty; Exclusion of Certain Damages

 

The 

BOMDMU Messaging and Call Stacking System

 is warranted to be free 

from defects in material and workmanship for one (1) year from the date of sale to 
the original purchaser. Any part of any Bogen product covered by this warranty 
that, with normal installation and use, becomes defective (as confirmed by Bogen 
upon inspection) during the applicable warranty period, will be repaired or 
replaced by Bogen, at Bogen’s option, provided the product is shipped insured 
and prepaid to: Bogen Factory Service Department, 50 Spring Street, Ramsey, 
NJ 07446, USA. Repaired or replacement product will be returned to you freight 
prepaid. This warranty does not extend to any of our products that have been 
subjected to abuse, misuse, improper storage, neglect, accident, improper 
installation or have been modified or repaired or altered in any manner 
whatsoever, or where the serial number or date code has been removed or 
defaced.

 

THE FOREGOING LIMITED WARRANTY IS BOGEN’S SOLE AND EXCLUSIVE 
WARRANTY AND THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY. 
BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND, EITHER EXPRESS 
OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR 
FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND 
EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW.

 Bogen's 

liability arising out of the manufacture, sale or supplying of products or their use or 
disposition, whether based upon warranty, contract, tort or otherwise, shall be 
limited to the price of the product. IN NO EVENT SHALL BOGEN BE LIABLE 
FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING, 
BUT NOT LIMITED TO, LOSS OF PROFITS, LOSS OF DATA OR LOSS OF 
USE DAMAGES) ARISING OUT OF THE MANUFACTURE, SALE OR 
SUPPLYING OF PRODUCTS, EVEN IF BOGEN HAS BEEN ADVISED OF THE 
POSSIBILITY OF SUCH DAMAGES OR LOSSES. Some States do not allow the 
exclusion or limitation of incidental or consequential damages, so the above 
limitation or exclusion may not apply to you. This warranty gives you specific legal 
rights, and you may also have other rights which vary from State to State.

 

Products that are out of warranty will also be repaired by the Bogen Factory 
Service Department -- same address as above or call 201-934-8500. The parts 
and labor involved in these repairs are warranted for 90 days when repaired by 
the Bogen Factory Service Department. All shipping charges in addition to parts 
and labor charges will be at the owner's expense. All returns require a Return 
Authorization number. For most efficient warranty or repair service, please include 
a description of the failure.

 

Products manufactured and labeled by other companies may be covered by 
warranties offered by such companies. Please call Bogen Customer Service or 
refer to product packaging for manufacturer’s warranty for non-Bogen branded 
products. 
 
12/2008

 

Содержание BOMDMU

Страница 1: ...BOMDMU Messaging and Call Stacking System User s Manual 2012 Bogen Communications Inc All rights reserved Specifications subject to change without notice 54 2213 01A 1208 ...

Страница 2: ...mounted CAUTION If any wiring from the system leaves the premises you must use proper electrical protectors Regulations FCC Part 15 Radio Frequency Interference The BOMDMU generates and uses radio frequency energy and if not installed and used in strict accordance with the manufacturer s instructions may cause interference to radio and television reception Unit complies with the limits for Class A...

Страница 3: ...und Music Input Volume 7 2 2 10 Background Music Input Connector 8 2 2 11 Audio Output Mode Switch 8 2 2 12 Output Volume 8 2 2 13 System Audio Control Connector 8 2 2 14 Configuration Switches 9 2 2 15 Messaging Playback Auxiliary Interface 13 2 2 16 Paging Control and Status Auxiliary Interface 13 3 PAGE STACKING FEEDBACK ELIMINATION OPERATION 14 3 1 Page Recording 15 3 2 Record Activation Metho...

Страница 4: ...verrides the stacking and messaging functions and provides immediate real time access to the paging system PRE RECORDED MESSAGES For security and general public address messaging a pre recorded messaging sub system has been included Access both Record and Play functions of up to 99 messages 8 minutes of audio from an extension on your host telephone system Ten 10 start contacts have also been prov...

Страница 5: ...tones DIP selectable Pre Page Tone DIP selectable POWER Power Pack 12V DC 1 Amp UL and CSA MEMORY Type FLASH Page Stacking 4 minutes per page input channel Messaging 8 minutes MESSAGE CONTROL of messages 99 Record Control DTMF control from messaging input Play Control Triggered from DTMF on messaging input or start contacts 10 PAGE CONTROL Priority Control contact is offered on the Priority Input ...

Страница 6: ... into which you can plug the power pack This outlet should NOT be controlled by a wall switch 3 Make cable connections from the BOMDMU to the PBX or audio source and the Paging system 4 Set DIP switches to the desired operation 5 Connect the power supply System OK LED should illuminate GREEN 6 Test unit operation 2 2 Hardware Description FRONT The BOMDMU is a standard 1RU 19 rack mount chassis The...

Страница 7: ...cators are global indicators that indicate that a particular function is active on any or all of the inputs on the system System OK LED Green indicates unit is ON Flashing indicates an error condition contact the factory for more information should this occur Recording LED Red indicates that a recording session is active on any one of the paging inputs Playing LED Green indicates that the audio ou...

Страница 8: ...connector 6 position All pages to be recorded are input to the device through these connectors 1 Abort stops and deletes the recording when connected to Ground Pin 5 2 Record input connect to Ground Pin 5 to activate Unit records for duration of closure 3 Audio ring return 4 Audio tip signal 5 System Ground power return 6 Not used 2 2 4 Port Configuration Switch Paging Channels 1 3 Priority Input ...

Страница 9: ...s 24V DC talk battery Compatible with loop start trunk ports 2 2 7 Messaging Audio Control Input Input RJ12 style connector 6 position Operation of the messaging portion of the system is provided through this interface 1 Not used 2 Not used 3 Audio ring return 4 Audio tip signal 5 Not used 6 Not used 2 2 8 Messaging Mode Switch Analog Station LEFT Position Impedance 900 ohm voltage for ring trip 7...

Страница 10: ...el 500 mW 8 ohm Use this for longer runs or if not enough level can be reached with the line level output 2 2 12 Output Volume Controls the audio output volume level delivered to the paging system It is shipped with 1 1 gain factory set Adjusting this input clockwise increases the level and counter clockwise rotation decreases the level of the device 2 2 13 System Audio Control Connector Output RJ...

Страница 11: ...ivation Method The method with which the user will enter the record mode Not in use NOTE Record Input activation is always available regardless of switch settings A maintained contact closure on any channel s record input will start the recording process on that channel for the duration of the closure 3 Active Not Active DTMF Tone Stripping DTMF tones recorded at the beginning of an audio message ...

Страница 12: ...10 11 ...

Страница 13: ...ll abort that particular recording 2 tones 7 Enable Abort This would allow a caller to abort a page being recorded by pressing the button two times within one second The recording will immediately be aborted and the busy back tone sent to the input A single sign during the recording will not have any effect Disable 8 Auto Play Play Mode Allows for automatic playback of page after recording Manual ...

Страница 14: ...message 1 when connected to ground 3 Play 2 Plays message 2 when connected to ground 4 Play 3 Plays message 3 when connected to ground 5 Play 4 Plays message 4 when connected to ground 6 Play 5 Plays message 5 when connected to ground 7 Play 6 Plays message 6 when connected to ground 8 Play 7 Plays message 7 when connected to ground 9 Play 8 Plays message 8 when connected to ground 10 Play 9 Plays...

Страница 15: ...ording time Pages exceeding this will be aborted and a busy back tone is generated Recordings that reach the end of memory are considered incomplete These pages are aborted and a busy back tone is generated If the memory is filled and a new recording command is offered the BOMDMU will not go into record mode and a busy back tone will be output to tell the user that the system is not available The ...

Страница 16: ...ing process for the duration of the page Valid for Analog Station and Loop Start modes Audio Sense Setup Switches 1 OFF 2 ON For record activation without a separate switch closure or loop current The BOMDMU will start recording when the audio sensor goes active and will stop when the audio sensor is inactive for three seconds Valid for Analog Station Loop Start and Dry Loop modes DTMF Activation ...

Страница 17: ...AGING PRE RECORDED The BOMDMU offers a pre recorded messaging system for quick and easy access to standard or frequently used pages This system allows messages to be recorded and permanently stored in FLASH memory Playback is provided via DTMF command or contact closure The messaging portion of the BOMDMU can store up to 99 messages in 8 minutes of memory DTMF Commands Code Name Description End Us...

Страница 18: ...audio interface for your zone controller amplifier or public address system All audio from the paging channels priority input messaging system and BGM input is routed to this output The BOMDMU manages stored pages on a first in first out basis This means that pages will be played in the order they were successfully completed and or triggered independent of the particular input Only the priority in...

Страница 19: ...Appendix BOMDMU Connection to Override to PCMTIM BOMDMU Connection to Override to UTI1 1 2 18 ...

Страница 20: ...ng c ing ck ges and nput ss s of vices U also e yed rd BOMDMU Connection to Override to UTI312 ...

Страница 21: ...___ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ___________________________________________________...

Страница 22: ...LOWABLE BY LAW Bogen s liability arising out of the manufacture sale or supplying of products or their use or disposition whether based upon warranty contract tort or otherwise shall be limited to the price of the product IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS LOSS OF DATA OR LOSS OF USE DAMAGES ARISING OUT OF ...

Страница 23: ...50 Spring Street Ramsey NJ 07446 USA Te 201 934 8500 Fax 201 934 9832 www bogen com ...

Отзывы: