Bogen BOMDMU Скачать руководство пользователя страница 15

 
 

Not Used 

Not Used 

Busy Common 

Common for the busy relay 

Busy Relay 

Activates when system is recording or 
playing a message. 

Playing Common 

Common for the Playing Relay. 

10 

Playing Relay 

Activates when system is playing. 

11 

Recording Common 

Common for the Recording Relay. 

12 

Recording Relay 

Activates when the system is 
recording. 

 

3. PAGE STACKING, FEEDBACK ELIMINATION OPERATION 

 

The BOMDMU offers 3 channels of page stacking, intended for busy paging 
systems with multiple inputs. Each channel performs the following functions: 
 
1. It eliminates feedback by recording the incoming page(s), then playing them 

back after the user “hangs up”, eliminating any feedback loop. 

2. It is able to repeat each page allowing for better intelligibility in a noisy 

environment. 

3. It is capable of stacking up to 16 incoming pages per channel by recording 

incoming pages while playing back previously recorded ones on a first-in first-
out basis. 

 
Constraints: 
 

 

Each page is allowed a maximum of 1 minute recording time. Pages 
exceeding this will be aborted and a busy back tone is generated. 

 

Recordings that reach the end of memory are considered incomplete. 
These pages are aborted and a busy back tone is generated. If the 
memory is filled and a new recording command is offered, the 
BOMDMU will not go into record mode and a busy back tone will be 
output to tell the user that the system is not available. 

 

The recorded message must be a minimum of one second in length. 
Any message shorter than this will be aborted. 

 

The BOMDMU aborts pages that are comprised of 3 or more seconds of 
silence. The page is deleted and a busy back tone is generated. 

 
Other important features include the ability to Record/Regenerate, or Block 
DTMF tones for use in zone controller applications.  
 
The BOMDMU is designed to run in both Automatic and Manual modes. For 
paging applications the Automatic mode is the most widely used. This mode 
requires minimum installation time since it is the factory’s default setup. RJ12 
connectors are used for Audio inputs and outputs. Where logical, certain control 
signals are also provided on the individual RJ12 connectors associated with each 
input. 

 

 

2.2.5 Priority Audio/Control Input 

RJ12 style connector, 6 position.  Priority pages are input to the device 
through this connector. 
 

1. Not used. 
2. PRIORITY input, connect to Ground (Pin 5) to 

activate.  Priority active for duration of closure. 

3. PRIORITY Audio, ring/return. 
4. PRIORITY Audio, tip/signal. 
5. Ground. (power return).  
6. Not used. 

 

 

2.2.6 Priority Mode Switch 

Analog Station

 – LEFT Position. Impedance: 900-ohm, voltage for ring 

trip 75 to 105V (20 to 60 Hz). 

Dry Loop

 – CENTER Position. Configures audio input for 600-ohm, 

line-level (-10 dB nominal). 

Loop Start 

– RIGHT Position. Configures priority audio input for 900-

ohm and supplies 24V DC talk battery. Compatible with loop start trunk 
ports.  

2.2.7 Messaging Audio/Control Input 

Input, RJ12 style connector, 6 position.  Operation of the messaging 
portion of the system is provided through this interface. 
 

1. Not used. 
2. Not used. 
3. Audio, ring/return. 
4. Audio, tip/signal. 
5. Not used. 
6. Not used. 

 

2.2.8 Messaging Mode Switch 

Analog Station

 – LEFT Position. Impedance: 900-ohm, voltage for ring 

trip 75 to 105V (20 to 60 Hz). 

Dry Loop

 – CENTER Position. Configures audio input for 600-ohm, 

line-level (-10 dB nominal). 

Loop Start 

– RIGHT Position. Configures priority audio input for 900-

ohm and supplies 24V DC talk battery. Compatible with loop start trunk 
ports.  

2.2.9 Background Music Input Volume 

Controls the background music input volume level delivered to the audio 
output.  Adjusting this input clockwise increases the level, and counter-
clockwise rotation decreases the level of the background music.   

 

 

14 

Содержание BOMDMU

Страница 1: ...BOMDMU Messaging and Call Stacking System User s Manual 2012 Bogen Communications Inc All rights reserved Specifications subject to change without notice 54 2213 01A 1208 ...

Страница 2: ...mounted CAUTION If any wiring from the system leaves the premises you must use proper electrical protectors Regulations FCC Part 15 Radio Frequency Interference The BOMDMU generates and uses radio frequency energy and if not installed and used in strict accordance with the manufacturer s instructions may cause interference to radio and television reception Unit complies with the limits for Class A...

Страница 3: ...und Music Input Volume 7 2 2 10 Background Music Input Connector 8 2 2 11 Audio Output Mode Switch 8 2 2 12 Output Volume 8 2 2 13 System Audio Control Connector 8 2 2 14 Configuration Switches 9 2 2 15 Messaging Playback Auxiliary Interface 13 2 2 16 Paging Control and Status Auxiliary Interface 13 3 PAGE STACKING FEEDBACK ELIMINATION OPERATION 14 3 1 Page Recording 15 3 2 Record Activation Metho...

Страница 4: ...verrides the stacking and messaging functions and provides immediate real time access to the paging system PRE RECORDED MESSAGES For security and general public address messaging a pre recorded messaging sub system has been included Access both Record and Play functions of up to 99 messages 8 minutes of audio from an extension on your host telephone system Ten 10 start contacts have also been prov...

Страница 5: ...tones DIP selectable Pre Page Tone DIP selectable POWER Power Pack 12V DC 1 Amp UL and CSA MEMORY Type FLASH Page Stacking 4 minutes per page input channel Messaging 8 minutes MESSAGE CONTROL of messages 99 Record Control DTMF control from messaging input Play Control Triggered from DTMF on messaging input or start contacts 10 PAGE CONTROL Priority Control contact is offered on the Priority Input ...

Страница 6: ... into which you can plug the power pack This outlet should NOT be controlled by a wall switch 3 Make cable connections from the BOMDMU to the PBX or audio source and the Paging system 4 Set DIP switches to the desired operation 5 Connect the power supply System OK LED should illuminate GREEN 6 Test unit operation 2 2 Hardware Description FRONT The BOMDMU is a standard 1RU 19 rack mount chassis The...

Страница 7: ...cators are global indicators that indicate that a particular function is active on any or all of the inputs on the system System OK LED Green indicates unit is ON Flashing indicates an error condition contact the factory for more information should this occur Recording LED Red indicates that a recording session is active on any one of the paging inputs Playing LED Green indicates that the audio ou...

Страница 8: ...connector 6 position All pages to be recorded are input to the device through these connectors 1 Abort stops and deletes the recording when connected to Ground Pin 5 2 Record input connect to Ground Pin 5 to activate Unit records for duration of closure 3 Audio ring return 4 Audio tip signal 5 System Ground power return 6 Not used 2 2 4 Port Configuration Switch Paging Channels 1 3 Priority Input ...

Страница 9: ...s 24V DC talk battery Compatible with loop start trunk ports 2 2 7 Messaging Audio Control Input Input RJ12 style connector 6 position Operation of the messaging portion of the system is provided through this interface 1 Not used 2 Not used 3 Audio ring return 4 Audio tip signal 5 Not used 6 Not used 2 2 8 Messaging Mode Switch Analog Station LEFT Position Impedance 900 ohm voltage for ring trip 7...

Страница 10: ...el 500 mW 8 ohm Use this for longer runs or if not enough level can be reached with the line level output 2 2 12 Output Volume Controls the audio output volume level delivered to the paging system It is shipped with 1 1 gain factory set Adjusting this input clockwise increases the level and counter clockwise rotation decreases the level of the device 2 2 13 System Audio Control Connector Output RJ...

Страница 11: ...ivation Method The method with which the user will enter the record mode Not in use NOTE Record Input activation is always available regardless of switch settings A maintained contact closure on any channel s record input will start the recording process on that channel for the duration of the closure 3 Active Not Active DTMF Tone Stripping DTMF tones recorded at the beginning of an audio message ...

Страница 12: ...10 11 ...

Страница 13: ...ll abort that particular recording 2 tones 7 Enable Abort This would allow a caller to abort a page being recorded by pressing the button two times within one second The recording will immediately be aborted and the busy back tone sent to the input A single sign during the recording will not have any effect Disable 8 Auto Play Play Mode Allows for automatic playback of page after recording Manual ...

Страница 14: ...message 1 when connected to ground 3 Play 2 Plays message 2 when connected to ground 4 Play 3 Plays message 3 when connected to ground 5 Play 4 Plays message 4 when connected to ground 6 Play 5 Plays message 5 when connected to ground 7 Play 6 Plays message 6 when connected to ground 8 Play 7 Plays message 7 when connected to ground 9 Play 8 Plays message 8 when connected to ground 10 Play 9 Plays...

Страница 15: ...ording time Pages exceeding this will be aborted and a busy back tone is generated Recordings that reach the end of memory are considered incomplete These pages are aborted and a busy back tone is generated If the memory is filled and a new recording command is offered the BOMDMU will not go into record mode and a busy back tone will be output to tell the user that the system is not available The ...

Страница 16: ...ing process for the duration of the page Valid for Analog Station and Loop Start modes Audio Sense Setup Switches 1 OFF 2 ON For record activation without a separate switch closure or loop current The BOMDMU will start recording when the audio sensor goes active and will stop when the audio sensor is inactive for three seconds Valid for Analog Station Loop Start and Dry Loop modes DTMF Activation ...

Страница 17: ...AGING PRE RECORDED The BOMDMU offers a pre recorded messaging system for quick and easy access to standard or frequently used pages This system allows messages to be recorded and permanently stored in FLASH memory Playback is provided via DTMF command or contact closure The messaging portion of the BOMDMU can store up to 99 messages in 8 minutes of memory DTMF Commands Code Name Description End Us...

Страница 18: ...audio interface for your zone controller amplifier or public address system All audio from the paging channels priority input messaging system and BGM input is routed to this output The BOMDMU manages stored pages on a first in first out basis This means that pages will be played in the order they were successfully completed and or triggered independent of the particular input Only the priority in...

Страница 19: ...Appendix BOMDMU Connection to Override to PCMTIM BOMDMU Connection to Override to UTI1 1 2 18 ...

Страница 20: ...ng c ing ck ges and nput ss s of vices U also e yed rd BOMDMU Connection to Override to UTI312 ...

Страница 21: ...___ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ____________________________________________________________________ ___________________________________________________...

Страница 22: ...LOWABLE BY LAW Bogen s liability arising out of the manufacture sale or supplying of products or their use or disposition whether based upon warranty contract tort or otherwise shall be limited to the price of the product IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS LOSS OF DATA OR LOSS OF USE DAMAGES ARISING OUT OF ...

Страница 23: ...50 Spring Street Ramsey NJ 07446 USA Te 201 934 8500 Fax 201 934 9832 www bogen com ...

Отзывы: