Technician Level Programming
Setting the IP Address from the LCD Display
1) Type in 6063 at the main screen to enter the technician level menu mode.
2) Press the NO/CANCEL button until the display reads “Set the IP Address?” as shown in Fig 3.19.
3) Press the YES/ENTER button.
4) Type in the 12 digit IP address using the keypad. (e.g. 192.168.000.012) Setting the IP address to 000.000.000.000 automatically sets the unit
for DHCP enabled. Any other value disables DHCP and considers it a static IP.
5) To exit and return to the main screen, continue to press the NO/CANCEL button until the main screen appears.
Setting the Subnet Mask from the LCD Display
1) Type in 6063 at the main screen to enter the technician level menu mode.
2) Press the NO/CANCEL button until the display reads “Set the Subnet Mask?” as shown in Fig 3.20.
3) Press the YES/ENTER button.
4) Type in the 12 digit gateway address using the keypad. (e.g. 255.255.255.000)
5) To exit and return to the main screen, continue to press the NO/CANCEL button until the main screen appears.