General
1.5
Brief operating instructions
Page 10
BOGE Operating instructions trinity
Messages
If !!!*** xx ***!!! appears on the display
(xx = blinking number), this is an error message according to the following
table:
By pressing the
ENTER key
when the specific message is displayed, the
message is acknowledged and the previous display reappears – presupposed
the reason responsible for the message has been eliminated.
Parameterization codes
Num-
ber
Meaning
Remedy
Others
16
Pressure transmitter is defective
Replace pressure transmitter
25
Balance storage
Repeat software loading
Replace control
32
Pressure transmitter line break
Correctly connect pressure trans-
mitter (+24 V to 1)
Replace pressure transmitter or its plug
Parameter type
Code
Remark
Page
Pressure target values
360
H lowest switching point
6
Number of compr Interval
time
832
Set interval time to 0 h = timer operation
7
Switching times
798
All priority sequences can be set, 000 = general output lock return:
Hold
arrow key
and then press the
ENTER key
at the same time
7
Timer
010
Day: 1 = Monday, 7 = Sunday
8