BOGE Operating instructions for C 10 L...C 20 L series screw compressors
Page 27
Installation
3.5
Commissioning
Fig. 3.3: Suction controller
Refrigeration
compressed air dryer
Before commissioning the refrigeration compressed air dryer read attached
operating instructions.
Caution: Risk of injury!
Switch off the main switch and secure against unintentional switching-on.
–
Unscrew the plug on the
suction controller (1).
–
Fill approx. 0.026 gallon
compressor oil into the
suction controller.
–
Reclose the controller
using the plug.
–
Prior to switching on the
compressor wait for ap-
prox.10 min until the oil
has spread evenly. Then
switch the compressor
on and immediately off
again.
–
After approx.10 sec. the
compressor can be start-
ed.
Caution: Risk of injury!
Observe all safety notes specified in the attached operating instructions when
working with coolants!