                        BM-300 

3.2 Adjustment and Operation 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 

 

3.2.1 Brightness Adjustment

Fig.16

 

1.

 

Connect  the  power  cord  and  set  the  main  switch  to 

”state (ON). 

2.

 

Turning the brightness adjustment knob clockwise, the 

voltage  raise,  and  the  brightness  strengthen;  whereas 

turning at the contra direction, the voltage decline, and 

the brightness weaken. 

2.T

 

Using the microscope with low voltage in the voltage 

range can prolong the service life of the bulb. 

3.3.2 Placing the Specimen

Fig.17

 

1.  Place  the  specimen   in  the  center  of  the  mechanical 
stage and use the stage clips to clamp it.

 

2. Turn the portrait and lateral adjustment 

  knob 

 of the mechanical ruler, move the specimen to the 

required position. 

 

Be  careful  when  changing  the  objective.  If  you 

finish  the  observation  with  the  short  working  distance 

objective, and want to change another one, be careful of 

not letting the objective touch the specimen. 

3.3.3 Focusing the Specimen

Fig.18

 

1.  Focus  the  specimen  with  10X  objective.  To  avoid  the 
objective  touching  the  specimen  during  focusing,  you 
should raise the mechanical stage to let the specimen close 
to the objective at first, then slowly separate them to bring 
the specimen to focus. 

 

 

 

 

 

 

Fig.13 

Fig.15 

Fig.14 

Содержание BM-300

Страница 1: ...his manual is for biological microscope Model BM 300 To ensure the safety obtain optimum performance and to familiarize yourself fully with the use of this microscope it is recommended strongly that y...

Страница 2: ...R NOTICES 2 1 Components Name 3 2 Assembly 4 2 1 Assembly Diagram 2 2 Assembly Procedures 4 5 3 Adjustment 8 3 1 Adjustment Set Diaphragm 8 3 2 Adjustment Procedures 11 4 Technical Specifications 13 5...

Страница 3: ...ngeover switch 8 Always use the power cord provided by Novel II Maintenance and Care 1 All the lenses have been adjusted properly do not dismount them by yourself please 2 The nosepiece and coarse and...

Страница 4: ...3 1 Components Name BM 300 Eyepiece Binocular viewing head Nosepiece Objective Main body...

Страница 5: ...nents The number in the figure shows the assembly steps Before installing be sure every components is clean do not score any parts or glass surface Keep well with hexagon wrench provided When changing...

Страница 6: ...ing head Fig 1 2 Insert the binocular viewing head into the microscope head and turn it to a proper position then screw down the bolt to fix it 2 2 2 Installing the eyepiece Fig3 4 Insert the eyepiece...

Страница 7: ...agnification Installing objective this way will make the change of magnification to be easier during using Clean the objective regularly for lens is susceptible to dust When operating use 10 magnifica...

Страница 8: ...power supply receptacle Make sure the connection is well Do use the supplied power cord all the time If lost or damaged select the same standard cord please A wide range of voltage like 100V 240V is...

Страница 9: ...peration BM 300 3 1 Adjustment set diagram Fig 14 15 Right Fine Focus Knob Right Coarse Focus Knob Tension Adjustment Collar Main Switch Portrait Adjustment Knob Lateral Adjustment Knob Brightness Adj...

Страница 10: ...9 BM 300 Left Coarse Focus Knob Interpupillar Distance Indicator Fig 12 Clocking Set Condenser Focusing Knob Left Fine Focus Knob Aperture Iris Diaphragm Collar Indicator...

Страница 11: ...center of the mechanical stage and use the stage clips to clamp it 2 Turn the portrait and lateral adjustment knob of the mechanical ruler move the specimen to the required position Be careful when ch...

Страница 12: ...n one The condenser and the objective are coaxial It has been adjusted before leaving factory so the user needn t to adjust them by self The highest position of the condenser has been adjusted too It...

Страница 13: ...viewing head is the diopter in use 3 3 8 Adjusting the tension adjustment collar Fig 23 Turn the tension adjustment collar with your fingers When the collar is turned in the direction of the arrow te...

Страница 14: ...00 Focusing Coaxial Coarse and Fine Adjustment Moving Range20mm Fine Division 0 002mm Condenser Abbe Condenser NA 1 25 Stage Double Layers Mechanical Stage 140mm 140mm Moving Range 75 50mm Illuminatio...

Страница 15: ...ead 1 Condenser Abbe Condenser NA 1 25 1 Nosepiece Quadruple 1 3W LED 1 Illumination Spare BGX 1 20 0 25A Fuse 2 2 Eyepiece 10 Wide Field Plan Eyepiece 18 mm 2 10 Wide Field Plan Eyepiece 20 mm 2 Infi...

Страница 16: ...t especially for 40X objectives Wipe the oil A lens the objective condenser eyepiece or collector is dirty Clean it Immersion oil is not used with the 100x objective Use specified oil Air bubbles exis...

Страница 17: ...at of the other Interpupillary distance is incorrect Adjust interpupillary distance The diopter is not proper Adjust the diopter properly 5 Observation is tiring The brightness of the illumination is...

Отзывы: