62
It is possible to add the key number of the server to make the distribution
secure.
The “Force master clock time setting with respect to server on starting” option
will order the master clock to connect to the address of the server and take the
time there on starting.
The master clock is the NTP server
In NTP server mode, the Sigma sends the time to the selected IP addresses
with the selected mode of transmission.
The clients will be in Broadcast or Multicast mode.
For unicast client, you will have to enter the IP address of the master clock in
the configuration parameters of the client.
In the menu, select “Alarms” (see page 46).
Sigma system alarms can be sent by e-mail to the selected addresses (up to 5
addresses), and by SNMP.