radio pictogram flashes to indicate that the search is under way. The display
shows the construction of the time message as and when
the data arrives.
Sync (implulse) :
Select with the [+] button the impulse type
between :
Min
: Minutes // impulses network.
1:2M
: ½ Minutes // impulses network.
AFn
: Afnor NFS87500A coded time network. After 24 hours without
signal, the clock stops.
AFni
: Afnor NFS87500A coded time network. After 24 hours without
signal, the clock keeps on working on its own time basis.
IriG
: Irig B coded time network.
The default configuration of the AFNOR receiver clock is AFNORi.
For a coded time pulse AFNOR or Irig-B, press [SELECT] to obtain the “coded
time type” menu.
If the clock is in mode COD, the time displayed is the time received from master
clock.
If the clock is in mode LOC, the time displayed depend on
the offset selected in the Time mode menu (Seasonal
change and offset change).
DHF
: activation of the DHF synchronisation card.
nor
: normal mode, the clock is already associated to a DHF
transmitter.
Press [SELECT] button to access to the dynamic
DHF synchro menu. This menu allows you to
check the time signal reception. The display
shows the construction of the time message as
and when the data arrives. Press [SELECT]
button to exit this menu.
INIT
: this mode forces the clock to search a
DHF transmitter. After selecting this mode, the
clock comes back to the time display, initialised
to 00h00 01/01/2000. As soon as the clock finds
a DHF transmitter, the clock is synchronised and
switched to “nor” mode. The clock is now
associated and synchronised by this transmitter.
45