5.
Press the [SELECT] button. Adjusting the temperature offset. Variation, using the [+] button
between –9.5°C and +9.5°C by increments of 0.5 (on leaving the
factory, an adjustment can be made). The current temperature is
displayed on the second line, taking the offset in consideration. The
temperature is read every 10 seconds.
6.
Press [SELECT] to obtain the Test display menu. This menu enables
you to check that all the clock segments are giving the correct
display. On the Opalys Date clock, the [+] button enables you to
scroll the character table.
7.
Press [SELECT]. The Correction menu appears. This enables you to
correct the time base manually. On leaving the factory, the value of
the offset is 0. The value of this offset may vary (using the [+])
between -9s99 and +9s99 per 10ms step (#0.12 ppm). The addition
of this daily offset to the time base will be spread over 24 hours.
8.
Press [SELECT] again to exit the technician menu and return to the
time display.
Reminder
: At any time, holding down the [SELECT] button, then
pressing the [+] button quickly, goes to normal display mode and
exits the configuration menu.
If no buttons are pressed for 10 minutes, the clock returns automatically to time display
mode.
41