28
6/ To open a panel, put the panel in the maintenace position by pulling it toward you (See plan page 27).
7/ Remove the 6 screws and remove the side. Slide the the cover to the side
.
2.3 Electrical connection
The wiring of the BTX6425 HK is mostly done at the factory. These instructions deal with the wiring to be done on site.
The cables that need to be connected are: 2 power cables (240V AC), 2 communication (DATA) cables, 1 main power
cable.
1/ Put the main BTX6425 HK panel in the maintenance position and open it.
2/ Connect the DATA cable (2 wires: white and brown) coming from the left BTX6104 HK panel to the
terminal block (A) of the BTX6425 HK. Do the same with the DATA cble coming from the right panel.
3/ Connect the power cable (3 wires: grenn/yellow, brrown and bleu) coming from the left BTX6104 HK
to the terminal block (B) of the BTX6425 HK. Do the same with the power cable of the right panel.
4/ Connect the main 240V + earth power cablr to the terminal block (C) of the BTX6425 HK (BODET
does not supply this cable (3x1,5²)).
5/ The Dips are set at the factory. Check that they are properly set (see page 31).
.
2.4 DIPs settings
The Dips are set at the factory, check if they are set as follow:
240V
240V
Data
BTX6025 HK
BTX6104 HK left
240V
Data
BTX6104 HK right
C
A
B