14
Opti-
3. Faults
FAULTS
SOLUTIONS
GLASS GETS DIRTY TOO QUICKLY
-Check that the fuel is not damp.
- Use the thermostat on 7-8.
- Check the position of the air detector.
- Open the baffl
e passage.
FAN Not working any more
- Check if the motor is working.
- Check the micro switch.
- Check (and replace) the variator fuse.
- Check the temperature switch (option).
- Check (and restore) the power supply.
FAN Operates but the output is weak
- Check that the wires of the speed variator are properly
positioned.
- Clean or replace the fi lters.
- Clean the impeller blades.
DRAUGHT
Too strong
Tighten the baffl
e passage (see “Adjusting baffl
es”)
- Contact your supplier.
DRAUGHT
Too weak, possibly with fumes leaking into the room
- Check the chimney (see installation instructions).
- Remove any obstructions.
- Open the baffl
e passage.
- Check if there is any improvement when the window is
open.
- Have the chimney swept.
Disruptions connected with weather conditions
- If this condition is permanent, consult your supplier.
THE FIRE LACKS INTENSITY
- Check that the fuel is not damp.
- Check the thermostat (put it on 7-8 and check its move-
ment).
- Empty the ashtray.
- Unblock the distributor holes.
THERMOSTAT NO LONGER CLOSES:
- A foreign body is preventing the valve from closing
- Mechanical blockage
- Remove the foreign body.
- Replace the thermostat.
THERMOSTAT STAYS SHUT:
1. On COLD, the valve only raises from medium positions
2. On COLD, the valve does not raise any more
1) Recalibrate the setting.
2) Replace the thermostat (it has been damaged following
major overheating of the fi replace).
UNCONTROLLABLE FIRE:
- DOOR of ashtray open or not airtight
- DOOR of fi replace not airtight
- THERMOSTAT does not shut
- Check the ashtray door closes properly.
- Check the seal, and replace it where necessary.
- Readjust the door seal setting.
- Readjust the position of the lock roller.
- Check operation of the thermostat.
In the event of a CHIMNEY FIRE, close immediately the door and the
ashtray door, turn off the thermostat.
Содержание Optifire OPTI700
Страница 2: ...2 Opti For the chimney sweep tick the correct position of the ba es see 1 5...
Страница 15: ...Opti re 15 4 Spare parts...
Страница 17: ...Opti re 17...
Страница 19: ...Opti re 19...
Страница 27: ...Opti re 26 13 5 10 13 5 10 Opti re 703 1 Characteristics...
Страница 28: ...27 Opti re 13 5 10 13 5 10 Opti re 704...
Страница 31: ...Opti re 30 Opti re 763D...
Страница 32: ...31 Opti re Opti re 764D...