8
- allow the drainage of condensates
- allow residues to drain into the firebox when sweeping.
Connect only one appliance per flue.
The chimney outlet (stump) must be located outside wind influence zones and outside the
depression zone of the building. It must also be fitted with a cap to prevent rainwater from
draining into the stove.
If these requirements cannot be guaranteed the flue must be lined, renovated or a new
chimney must be installed.
(!) Failure to comply with these recommendations may lead to various consequences
(difficult lighting, backflow, too little or too much draught, damage to the appliance or
chimney flue, risk of fire, etc.). Do not hesitate to ask a professional for advice.
"Efficience" ducts (Poujoulat triple skin)
The Infire Easy stoves are compatible with the "Efficience" ducts from the Poujoulat
manufacturer. The "Efficience" duct must be a minimum of 4m, and a maximum of 8m high.
Refer to the recommendation sheet from Poujoulat.
Connection to the chimney flue
The stove is equipped with an outlet flue collar to connect a 180mm duct.
The connection to the chimney flue must be tight.
For connection to a flexible duct, use the stainless steel flue collar supplied. Securely fix the
flexible duct to the stainless steel flue collar, and fix the stainless steel flue collar to the
heater with the two M5 screws (8mm socket) present on the heating element.
1.5.
Electrical connection.
As the stove is equipped with electronic ventilation and combustion control, an electrical
source (220 VAC 50Hz) must be available nearby.
See chapter "Easy System".
1.6.
Finishing frame.
There are 3 types of standard frameworks available:
- 4mm frame (see picture on the left);
- 30mm 4-sided frame (see image on the right);
- 30mm 3-sided frame.
To fit or remove the frame, first remove the door and the side covers.
To remove the door, open it 90° and lift it 3cm.