40
3. Use the software controls to turn on the extruder to the correct working temperature of
the filament. Once the extruder reaches the set temperature, use the software control to
feed the filament into the nozzle. Check to make sure the extruder stepper motor rotates
in the correct direction.
Homing and Z Height Adjustment
1. Home the axles to ensure that the limit switches are connected correctly
Note that the switches are wired normally closed. If the limit switches do not
function troubleshoot the switches using the M119 code.
2. Set the firmware for Z max length to 210 mm.
3. Use the G0 Z20 command to move the printer close to the bed.
4. Slowly move the Z axis close to the bed. Use a gage or business card to get the right
side of the bed the set distance to the nozzle. (business card is around 0.35 mm thick)
5. Once you get the set height for the left side, move the Y axis to the right a little at a
time while adjusting the height of the nozzle from the bed to the set height my manually
adjusting the right Z stepper motor.
6. Repeat steps 4 and 5 until the nozzle is the same distance from the bed for Y travel.
Содержание RP8