Installation for Tube Connections

1.  Using the soap tubes, 

connect the bottom 

end of all control boxes 

together. Cut the 

tubing to the shortest 

length between units 

to ensure that the 

tubing has minimal 

slack, while the ends 

of the tubing fits 

completely into each T 

connector. 

2.  Connect the soap tube into the valve fitting of soap 

reservoir tank.

3.  Connect a shut-off valve switch connector to the 

tubing at the end of the soap supply system. Make 

sure that the shut-off valve switch at the end of the 

multi-feed system is in the horizontal (closed) position. 

Reference image below currently shows in the vertical 

(open) position.

4.  For each soap dispenser in the system, plug in the AC 

adapter into the control box.

5.  For the control box on the soap reservoir tank, follow 

the diagram below to connect the appropriate wires 

and AC Adapter.

6.  Ensure that the valve switches that are directly 

connected into the control boxes and reservoir tank are 

in the vertical (open) position.

Fill Instructions:

1.  Use the provided Suction Cup to remove the fill port cap.

2.  Insert the provided funnel into the fill port, then pour the liquid soap through the funnel.

3.  An audible signal will sound for about 15 seconds to indicate sufficient soap level. Stop refilling when the warning is 

heard. Please ensure to use the correct type of soap that is compatible with the dispenser type purchased with the 

system. Using the incorrect type of soap may cause performance issues.

To Operate:

Prime Multi-Feed System: Ensure all valve switches on each soap dispenser and on the soap reservoir tank are open to 

allow soap to flow through the tube and the multi-feed system to prime.  For more efficient priming, open the shut-off 

valve at the end of the system and place end of tube in a container to catch any soap.  This will allow the air in the line to 

be removed and soap to flow faster to each dispenser.  Once the soap has reached the shut-off valve, close the valve and 

remove the container.  Then activate the sensor by hand until soap is dispensed on all soap dispensers in the system.

Standard Operation: Place hand below spout in front of the IR sensor to dispense controlled amount of soap.

Routine Cleaning and Maintenance: 

It is recommended to clean the faucet once a week – Wipe the spout above the counter with a soft cleaning cloth. Water 

or neutral detergent as cleaning solutions would be acceptable. Do not use cleaning solutions that contain acidic, alkaline, 

corrosive, or abrasive chemicals.

Depending on usage frequency, it is recommended to conduct visual inspection of the soap reservoir tank to check for 

any impurities or coagulation. To ensure the best performance of the product, remove and clean the soap reservoir tank 

as needed. 

Cleaning the Nozzle (B-820-248 Foam Soap Dispenser Only)

When foam soap volume is reduced, remove the nozzle to clean the mesh screen.  It is 

recommended to clean the nozzle every three months, but may vary depending on usage.

1.  Disconnect the power supply from the control box.

2.  Use a Phillips screwdriver to unscrew the nozzle from the spout.

3.  Rinse the foaming mesh screen and nozzle with water and screw the nozzle back into the spout. 

Cleaning the Soap Pump

1.  Disconnect the power supply, all cables and tubes from the 

control box.

2.  Turn the valve switch for the soap tubes to the horizontal 

OFF position.

3.  Use a Phillips screwdriver to remove the screw that secures 

the control box on the base plate. Then, pull the control box 

upwards to remove the soap tank from the base plate.

4.  Pull the soap pump component from the control box.

5.  Place the soap pump under running water. Squeeze the soap 

pump so that water can rinse inside the soap pump.

6.  Insert the soap pump back into the control box. 

7.  Push the control box back into the base plate and secure the 

Phillips screw at the back.

8.  Reconnect the AC adapter plug, all cables, air and soap tubes 

from the control box and soap tank. 

9.  Turn the valve switch for the soap tubes to the vertical ON 

position.

5

4

Содержание B-820-258

Страница 1: ...t 5 91 150 mm from the center of the mounting hole to the side and back wall The horizontal clearance required between the soap reservoir and side wall is 1 25mm In the United States BOBRICK WASHROOM EQUIPMENT INC New York 200 Commerce Drive Clifton Park NY 12065 1350 Tel 518 877 7444 Fax 518 877 5029 Los Angeles 6901 Tujunga Ave North Hollywood CA 91605 6213 Tel 818 982 9600 Fax 818 503 9287 or e...

Страница 2: ...o the threaded stem to secure the assembly 5 Use the Wall Mounting Template to determine the best installation location on the rear wall based on the reach of soap tube The vertical clearance from the bottom of the countertop to the mounting screw for the soap pump at the rear wall should be a minimum of 4 100 mm and maximum of 18 450 mm Then tape the Wall Mounting Template to the wall drill two 0...

Страница 3: ...e line to be removed and soap to flow faster to each dispenser Once the soap has reached the shut off valve close the valve and remove the container Then activate the sensor by hand until soap is dispensed on all soap dispensers in the system Standard Operation Place hand below spout in front of the IR sensor to dispense controlled amount of soap Routine Cleaning and Maintenance It is recommended ...

Страница 4: ...tank is pushed all the way into the plastic fill port properly seated to prevent soap from leaking at mating connection Check if soap reservoir tank is damaged punctured Check if or soap tube is damaged or not connected properly Observed Issue Recommended Solution Unit does not respond at all or has delayed response Check all wire connections from the spout into the control box Clean and remove an...

Отзывы: