Bobrick B-820-258 Скачать руководство пользователя страница 2

T connector

Drain connector

110 cm

45 cm

3 cm

2.5cm

3 cm

Soap tube is leveled.

Soap tube has excessive slack.

A

B

Rubber Washer

Nylon Washer

Mounting

Nut

Counter

Rubber 

Washer

Locking 

Nut

Bracket

Recommendation on Tubing Configuration

• 

The soap tube connectors from soap pumps should be 

no higher than that of the soap reservoir tank.

• 

Recommended tubing distance between each soap 

pump should be no longer than 43.31" (1,100 mm).

• 

The vertical slack of the tubing running from the soap 

reservoir tank to the nearest soap pump should be at 

least 1.18" (30 mm).

• 

Keep all soap pumps at the same height so that the 

soap tubes between units are leveled.  

• 

If each soap pump cannot be at the same height, 

the soap pump farthest from the soap reservoir tank 

should be the lowest in height. For the soap pumps in 

between the farthest soap pump and soap reservoir 

tank, the closer the soap pump is to the soap reservoir 

tank, the higher its installation location should be, 

while remaining in the recommended vertical clearance 

specified in the Clearances and Mounting Requirements 

section. 

• 

The soap pump in between the farthest soap pump 

and soap reservoir tank should not be lower than the 

neighboring soap pumps. 

• 

Cut the soap tubing to the shortest length between 

units to ensure that it has minimal slack.

Installation for B-820-258 (Liquid Soap Dispenser) /  

B-820-248 (Foam Soap Dispenser)

1.  Drill 1" diameter mounting hole per recommended 

Clearances and Mounting Requirements stated above.

2.  Place the above countertop rubber washer over 

mounting hole to align with profile of the dispenser.

3.  Insert the stem, tube and cable of the top assembly 

carefully through the mounting hole.

4.  Under the counter, first slide the below counter rubber 

washer and nylon washer through the stem, tube and 

cable of the top assembly. Then, screw the mounting 

nut into the threaded stem to secure the assembly.

5.  Use the Wall-Mounting Template to determine the best 

installation location on the rear wall based on the reach 

of soap tube. The vertical clearance from the bottom 

of the countertop to the mounting screw for the soap 

pump at the rear wall should be a minimum of 4" (100 

mm) and maximum of 18" (450 mm). Then, tape the 

Wall-Mounting Template to the wall, drill two 0.28" (7 

mm) holes and insert the wall anchors into the holes. 

A pack of three (3) 5/32" x 3/4" (4x19 mm) screws and 

three 8x25 mm plastic wall anchors are provided per 

soap pump unit.

Installation for B-820 (Multi-Feed Soap Reservoir) 

1.  Drill 2.38" diameter mounting hole per recommended 

Clearances and Mounting Requirements stated above.

2.  Insert the refilling 

assembly carefully 

through the mounting 

hole.

3.  Under the counter, slide the rubber pad and bracket 

through the stem of the refilling assembly first. Then, 

secure the components together by screwing the 

locking nut into the threaded stem of the refilling 

assembly.

Note:  Before installing the soap reservoir tank, 

disconnect the brown and black wire from the 

electronic control box.  Do not pinch or kink any wires.

4.  Slide the soap reservoir tank into the bracket, ensure 

the stem of the refilling assembly is aligned with the 

top opening of the soap tank, and the tank is pushed 

all the way into the plastic fill port to prevent soap from 

leaking. Then, slide the lower support bracket below the 

soap tank and secure the sides with thumb screws. 

6.  Thread the screws into the wall anchors and leave a 

space of 0.24" (6 mm) from the bottom of the screw 

head to the wall to hang the wall-mounting bracket on 

the control box.

7.  Hang the control box on the wall by sliding the keyhole 

slots on wall-mounting bracket at the back of the 

control box into the wall screws. Secure both wall 

screws afterwards

8.  Connect the wires from the dispenser assembly to the 

wires on the control box assembly (A). Then connect 

the soap tube from the spout assembly into the 

connector on the soap pump (B).

3

2

Содержание B-820-258

Страница 1: ...t 5 91 150 mm from the center of the mounting hole to the side and back wall The horizontal clearance required between the soap reservoir and side wall is 1 25mm In the United States BOBRICK WASHROOM EQUIPMENT INC New York 200 Commerce Drive Clifton Park NY 12065 1350 Tel 518 877 7444 Fax 518 877 5029 Los Angeles 6901 Tujunga Ave North Hollywood CA 91605 6213 Tel 818 982 9600 Fax 818 503 9287 or e...

Страница 2: ...o the threaded stem to secure the assembly 5 Use the Wall Mounting Template to determine the best installation location on the rear wall based on the reach of soap tube The vertical clearance from the bottom of the countertop to the mounting screw for the soap pump at the rear wall should be a minimum of 4 100 mm and maximum of 18 450 mm Then tape the Wall Mounting Template to the wall drill two 0...

Страница 3: ...e line to be removed and soap to flow faster to each dispenser Once the soap has reached the shut off valve close the valve and remove the container Then activate the sensor by hand until soap is dispensed on all soap dispensers in the system Standard Operation Place hand below spout in front of the IR sensor to dispense controlled amount of soap Routine Cleaning and Maintenance It is recommended ...

Страница 4: ...tank is pushed all the way into the plastic fill port properly seated to prevent soap from leaking at mating connection Check if soap reservoir tank is damaged punctured Check if or soap tube is damaged or not connected properly Observed Issue Recommended Solution Unit does not respond at all or has delayed response Check all wire connections from the spout into the control box Clean and remove an...