4.2 

230V SINGLE PHASE 

– With CS-7 Controller (CS-7 Controller provides on / off / high heat / low heat / fan only settings). 

 

Please make sure you have read the Safety instructions and that you are a suitably qualified electrician before continuing.  
Drawings show connections inside the black terminal box on the outside of the heater and the inside of the CS-7 Controller. 

Do NOT use power tools to undo or do up terminal screws.

 

Please Note:- Specified cable sizes are for typical installations, correction factors may need to be used when determining actual cable sizes. 

 
Standard Connection using CS-7 Controller 

Use 2.5mm² 3 Core Mains Cable (see note above). 
Use 2.5mm² 6 Core Cable to connect the heater to the CS-7 Controller (see note above). 
Remove  any  links 

that may be present in heater control box between terminals 1,2,3,4 or 5. 

 

Mains Cable 
Connect Brown wire 

– Terminal L. 

Connect Blue wire 

– Terminal N. 

Connect Green / Yellow wire 

– Terminal E or   

 

Heater to CS-7 Controller Cable 

– (Colours for reference only) 

Move the Dark Brown link cable from the centre switch terminal 1 to the centre switch terminal 3 (shown above by dark brown wire). 

Connect Brown wire 

– Terminal 1 or L of heater and Top Terminal L2 on right DP Switch of CS-7. 

Connect Grey wire 

– Terminal 2 of heater and Terminal L1 on right DP Switch of CS-7. 

Connect Red wire 

– Terminal 3 of heater and Centre Switch Terminal 1 of CS-7. 

Connect Black wire 

– Terminal 4 of heater and Terminal 1 on Left SP Switch of CS-7. 

Connect Yellow wire 

– Terminal 5 of heater and Top Terminal 2 on Left SP Switch of CS-7. 

Connect Green / Yellow wire 

– Terminal E or 

of heater and earth connection on CS-7. 

 

PLEASE CHECK ALL CONNECTIONS BEFORE TURNING ON AS INCORRECT WIRING IS NOT COVERED BY THE GUARANTEE. 

 

5. CHANGING MODE OF OPERATION 

 

The  heater  has  two  modes  of  operation  to  suit  different 
applications. 

These two modes are selected by a switch on top of the heater 
near the Power Supply Box. 

 

Mode I

 

With the switch on the top of the heater in the “I” position both 
the  heater  elements  and  the  fan  turn  on  and  off  with  the 
thermostat. This mode is best used when using the heater as a 
space  heater  but  may  give  long  periods  of  on  /  off  switching 
when the heater is used in a confined space. 

Mode II

 

With  the  switch on  the  top  of  the  heater  in  the  “II” position  the 
fan runs continuously and only the heating elements go on and 
off  with  the  thermostat  this  will  tend  to  improve  the  response 
time of the thermostat as air is always being moved around. 
If  you  use  this  heater  in  a  confined  space  we  recommend  you 
use this mode of operation. 
 

 

 