By default the controller is set to 5+2 days this means when programming Monday
– Friday settings
will all be the same and you can then program different settings for Saturday
– Sunday. If you require
7 day or 6+1 day settings enter defeult settings and adjust paramenters first (See section 5).
To adjust or program the time & temperature periods
a) Make sure the thermostat is on, or turn on by pressing
button.
b) Press and hold the
button for 3-5 seconds until the time starts to flash, display will also show
“ 1 2 3 4 5 ” and the first period symbol will show. Adjust the hours by pressing the
or
buttons. When correct, press
button and the minutes will flash. Set these by pressing the
or
buttons. When correct, press
button and the temperature will flash. Set this by pressing
the
or
buttons. When correct, press
and the second period symbol will show and the
hours will flash. Now repeat the above to set all 4 periods. Once set, the days will change to 6+7
and you repeat the above procedure to program Saturday and Sunday. Note
“ 1 2 3 4 5 ” on the
display while programming means you are setting all 5 Weekdays
“6+7” on the display while setting
means you are programming Saturday & Sunda
y. If you don’t press a button for appox 5 seconds
the controller will automatically store the settings and exit programming mode.
Run Modes
1
– Turn thermostat On or Off by pressing the
button.
2
– When “ON” press
to toggle between Auto mode
and Manual mode .
3
– When in Auto mode
you can override the set tempreture by pressing the
or
buttons.
This override will last until the next program period and is shown by both the
and symbols.
4
– When in Manual mode you can override the set tempreture by pressing the
or
buttons. Note:- The thermostat will stay in Manual mode with the same set temprature until you
switch it to Auto mode or turn the thermostat off.
At any time you can return to the auto temperature set point by pressing the
button until only
the Auto mode
shows.
Locking the controller
The controller has 2 lock settings selected in the default settings (see section 5). Half lock, when
set only allows the On / Off
button to be pressed. Full lock disables all buttons except the unlock
sequence. Putting the controller in lock mode indicated by a
symbol on the screen is done by
pressing and holding the
button until the
symbol appears. Unlocking is the reverse process.
Holiday Mode
Holiday days (count down) and temprature set point can be set so that the heating runs at a lower
temprature whilst you are away and reverts back to normal when you return. To access, make sure
controller is on and then press
button for 3-5 seconds until the screen displays Off change to
On by using the
or
buttons. Then press
button to set the number of days you are away.
Then press
button to set the temperature required while you are away. Holiday mode is shown
by a
symbol displayed on the screen. Once set, to exit holiday mode early press the
button.
3